Registration Dossier

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with generally accepted scientific standards and described in sufficient detail
Justification for type of information:
data is from experimental reports
Qualifier:
according to guideline
Guideline:
other: as mentioned below
Principles of method if other than guideline:
The particle size distribution of test item Methyl nicotinate (CAS No. 93-60-7 ) was determined by granulometric analysis with rotap sieve shaker.
GLP compliance:
not specified
Type of method:
sieving
Type of particle tested:
primary particle
Type of distribution:
counted distribution
Specific details on test material used for the study:
- Name of test material (as cited in study report): Methyl nicotinate
- Molecular formula: C7H7NO2
- Molecular weight: 137.137 g/mol
- Smiles notation: c1(C(OC)=O)cccnc1
- InChI: 1S/C7H7NO2/c1-10-7(9)6-3-2-4-8-5-6/h2-5H,1H3
- Substance type: Organic
- Physical state: Solid
Key result
Percentile:
D50
Remarks on result:
other: Mass median diameter
No.:
#1
Size:
150 µm
Distribution:
100 %
Remarks on result:
other: no other details mentioned

O BSERVATION TABLE

Amount of test item weighed (g)=10.896

Method run time(minute)=5 min

 

 

Sieve sizes(in

microns)

Weight of petridishes + test

item(g)

 

Test item quantity

retained after sieving (g)

 

Percentage(%)of

test item*

 
 150  57.161 10.563   100.00

 

Percentage of test item =   Test item retained on each sieve after sieving X 100

                                                   Original test item taken

 

Conclusions:
The particle size distribution of test item Methyl nicotinate (CAS No. 93-60-7 ) was determined by granulometric analysis with rotap sieve shaker. The particle size of methyl nicotinate was determined to be 150micron .
Executive summary:

The particle size distribution of test item Methyl nicotinate (CAS No. 93-60-7 ) was determined by granulometric analysis with rotap sieve shaker. The particle size of methyl nicotinate was determined to be 150micron .

Description of key information

The particle size distribution of test item Methyl nicotinate (CAS No. 93-60-7 ) was determined by granulometric analysis with rotap sieve shaker. The particle size of methyl nicotinate was determined to be 150micron .

Additional information

The particle size distribution of test item Methyl nicotinate (CAS No. 93-60-7 ) was determined by granulometric analysis with rotap sieve shaker. The particle size of methyl nicotinate was determined to be 150micron .