Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015-07-20
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study with acceptable restrictions
Remarks:
The study was conducted in accordance with a relevant test method and in compliance with a known quality system (ISO 9001:2008)
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Version / remarks:
2004
Deviations:
no
GLP compliance:
no
Other quality assurance:
other: ISO 9001:2008
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Flash point:
98.5 °C
Atm. press.:
1 013 hPa

Table 1: Flash point results

Test

Test series 1

temperature [°C]

Result

yes(+) / no(-)

Test series 2

temperature [°C]

Result

yes(+) / no(-)

1

94

-

93

-

2

95

-

94

-

3

96

-

95

-

4

97

-

96

-

5

98

+

97

+

6

98

+

97

+

 

Table 2: result summary

Test series

Measured value [°C]

Corrected value [°C]

1

98

99.2

2

97

98.2

Mean value*

98.5

*The mean value is calculated from test 1 and 2 and rounded to ± 0.5°C

Interpretation of results:
GHS criteria not met
Conclusions:
A flash point value of 98.5°C at 1013 hPa was determined for the substance using a relevant test method and in compliance with a known quality system. The result is considered to be reliable.

Description of key information

Flash point: 98.5°C at 1013 hPa (ISO 3679)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
98.5 °C

Additional information

A flash point value of 98.5°C at 1013 hPa was determined for the substance using a rapid equilibrium closed-cup method in accordance with ISO 3679 and in compliance with a known quality system (ISO 9001:2008). The result is considered to be reliable.

A measured flash point value of 98.5°C and a measured boiling point value of 197.1°C indicate that the substance is not classified for flammability in accordance with Regulation (EC) No. 1272/2008.