Registration Dossier

Physical & Chemical properties

Boiling point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling point/boiling range)
Deviations:
no
GLP compliance:
no
Type of method:
differential scanning calorimetry
Key result
Boiling pt.:
> 350 °C
Decomposition:
yes
Remarks:
no boiling point detected
Decomp. temp.:
ca. 350 °C
Remarks on result:
other: no boiling point detected! (decomposition temperature approx. 330°C
Conclusions:
No boiling point detected (Decomposition temperature approx. 350 °C)
Executive summary:

The purpose of the study was the evaluation of the boiling point according to OECD guideline 103. No boiling point was detected. The decomposition temperature of the test item was approx. 350 °C.

Description of key information

The determination of the boiling point was carried out according to OECD guideline 103. As a result, no boiling point detected. The decomposition temperature of the test substance was approx. 350 °C.

Key value for chemical safety assessment

Boiling point at 101 325 Pa:
350 °C

Additional information