Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
GLP compliance:
not specified
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Dynamic viscosity of test material:
0.134 mPa*s at 20°C
Specific details on test material used for the study:
Batch no.: lot # JBGJ0045R
Key result
Flash point:
> 150 °C
Atm. press.:
ca. 101.3 kPa
Remarks on result:
other: no flashing was observed up to 150°C
Conclusions:
Under the study condtions, no flashing was observed up to 150°C under standard atmospheric pressure (Pensky-Martens closed cup method).
Executive summary:

A study was conducted to determine the flash point of the test substance according to ISO 2719 (Pensky-Martens closed cup method). The method requires the test starts at 23°C below the flashpoint and be heated at 5-6°C/min to the flash point. Under the study condtions, no flashing was observed up to 150°C under standard atmospheric pressure (Martens, 2010).

Description of key information

The flash point was determined according to ISO 2719 (Pensky-Martens closed cup method) (Martens, 2010)

Key value for chemical safety assessment

Additional information

No flashing was observed up to 150°C at standard atmospheric pressure.