Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11 February 2014
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions
Qualifier:
no guideline followed
Principles of method if other than guideline:
- Principle of test: To obtain the particle size distribution of the ferrous gluconate sample by sieving and laser diffraction.

- Short description of test conditions: The sieves were assembled into two separate size ranges to allow for adequate agitation. For the size range 841 to 180 um, approximately 8.234 grams of sample was weighed and sieved. For the size range 150 to 29 um, approximately 8.867 grams of sample was weighted and sieved. The sample was taken from the top of the sample bottle. The sieves were agitated manually for approximately 1 minute. The contents of each sieve was removed and weighed. For the laser diffraction method, approximately 0.35g of the sample was transferred to the sampling chamber of the Horiba LA910 instrument until a transmittance of 75-90% was achieved. 300ml of Isopropyl Alcohol was used as dispersant fluid. The sample was constantly stirred during the particle size analysis in order to keep the heavier particles suspended. Also, the sample was sonicated for 60 seconds prior to the measurement interval. The Horiba LA910 Laser Diffraction Instrument operation conditions are listed below. Three replicate measurements were performed.

- Parameters analysed / observed:
Agitation Speed: 2
Circulation Speed: 2
Relative Refractive Index: 1.40-0.00i
Sonics Before Measurement: 60sec.
Sonics During Measurement: Off
Sampling Times: 40
GLP compliance:
no
Type of method:
Laser scattering/diffraction
Type of distribution:
volumetric distribution
Specific details on test material used for the study:
SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material:
Manufacturer Polytec International Ltd.
Batch # / Lot # 20131012
Mass median aerodynamic diameter:
ca. 370.1 µm
Key result
Percentile:
D50
Mean:
ca. 370.1 µm
St. dev.:
215.181
Percentile:
D50
Mean:
>= 342.8 - <= 407.7 µm
St. dev.:
215.181
Percentile:
D90
Mean:
>= 596.6 - <= 664.9 µm
St. dev.:
215.181
Percentile:
D10
Mean:
> 46.3 - <= 57.2 µm
St. dev.:
215.181

The particle size distribution from 841 – 28 microns obtained by a sieve method, of ferrous gluconate, is summarized in the following table.                                                       

Particle Size Distribution by the sieve method for ferrous gluconate.

 Sieve designation*  Sieve Size (microns)  Weight % of sample (Wt. %)
 ASTM 20  =841  43.1
  833   2.1
 ASTM 30  595  25.3
 ASTM 40  420  14.1
 ASTM 45  354  2.6
   240  0.0
 ASTM 80  180  8.8
   125  0.9
 ASTM 140 105  0.1
 ASTM 200  74  0.8
   58-62  0.2
 ASTM 325  45 0.1 
   28-32  0.0
   <28  0.0
   % Recovery  98.1%

* Sieves traceable to ASTM are listed as corresponding sieve number

A separate sample was analyzed by laser diffraction using Horiba LA-910 laser diffraction instrument. The average mean diameter was in the 358 µm size range and the average median diameter was 370 µm. The data clearly exhibits a bi-modal distribution with peaks at approximately 4 µm and ~400 µm. The largest population of particles is in the 400 µm size range. The complete laser diffraction volume-based results are shown in the following table. Comparison to the sieve method would indicate the sieve method is less effective in sieving particles >595 um which would appear to collagulate in the first sieve which is >841 um. 

Volume Based Particle Size Distribution Summary

 Sample ID     Run  Mean (µm)  Mode (µm)  Median (µm)  D10  D50  D90
 Sourscav 20131012  1  355.0  485.7  359.8  53.0  359.8  640.8
 Sourscav 20131012  2  384.9  551.4  407.7  57.2  407.7  664.9
 Sourscav 20131012  3  335.6  424.9  342.8 46.3   342.8  596.6
 Average PSD  AVE.  358.5  487.3  370.1  52.2  370.1  634.1
Conclusions:
The average median diameter was reported to be 370 µm. The data clearly exhibits a bi-modal distribution with peaks at approximately 4 µm and ~400 µm. The largest population of particles is in the 400 µm size range. The result is considered to be reliable.

Description of key information

A study was conducted using sieving and laser diffraction.
The average median diameter was 370 µm.

Additional information

The particle size distribution of ferrous gluconate was measured via sieving and via laser diffraction (Baldwin 2014, Particle Size Analysis of Iron Gluconate by sieving and laser diffraction).

The average median diameter was 370 µm.

The data clearly exhibits a bi-modal distribution with peaks at approximately 4 µm and ~400 µm. The largest population of particles is in the 400 µm size range.