Registration Dossier

Diss Factsheets

Environmental fate & pathways

Adsorption / desorption

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

The mean Koc for the test substance was determined to be 825 (log Koc of the test substance = 2.92).

Key value for chemical safety assessment

Additional information

A GLP compliant study was performed, according to OECD guideline 121, to determine the Koc coefficient of the test substance. The mean Kocfor the test substance was determined to be 825 (log Kocof the test substance = 2.92). The duplicate values of the log Koc for the test substance were considered acceptable since they fell within a range of ± 0.25 log units. The retention time of the test substance for each sample was 4.861 and 4.858 minutes.