Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

First-aid measures

Eye contact Holding the eyelids apart, flush eyes promptly with copious flowing water for at
least 20 minutes. Get medical attention immediately.
Skin contact
Notes to the physician Treat symptomatically and supportively
No specific antidote.
Remove contaminated clothing. Wash skin thoroughly with mild soap and plenty of
water for at least 15 minutes. Wash clothing before reuse. Get medical attention
immediately.
Inhalation In case of mist inhalation or breathing fumes released from heated material,
remove person to fresh air. Keep him quiet and warm. Apply artificial respiration if
necessary and get medical attention immediately.
Ingestion If swallowed, wash mouth thoroughly with plenty of water. Get medical attention
immediately
NOTE: Never give an unconscious person anything to drink
Most important symptoms and effects, acute or delayed
P201 - Obtain special instructions before use
P202 - Do not handle until all safety precautions have been read and understood
P281 - Use personal protective equipment as required
P308 + P313 - IF exposed or concerned: Get medical advice/ attention
P405 - Store locked up
P501 - Dispose of contents/container in accordance with national and international
regulations
Suspected of causing genetic defects
Potential environmental effects
Skin contact
Notes to the physician Treat symptomatically and supportively
No specific antidote.

Fire-fighting measures

Suitable extinguishing media
Material is not combustible. Use extinguishing media appropriate to surrounding
fire conditions.
Unusual fire and explosion hazards
Handling Keep containers tightly closed. Avoid bodily contact.
When heated to decomposition, may release poisonous and corrosive fumes of
NOx, HBr and CO.
Fire fighting procedure
Cool containers with water spray. In closed stores, provide fire-fighters with
self-contained breathing apparatus in positive pressure mode.

Accidental release measures

Personal precautions Wear canister type A or ABEK P3 respirator, butyl rubber gloves (0.7mm) and
boots.
Methods for cleaning up Absorb on sand or vermiculite and place in closed container for disposal. Ventilate
area and wash spill site after material pickup is complete

Handling and storage

Handling Keep containers tightly closed. Avoid bodily contact.
Storage Store in a dry, cool area away from incompatible materials (see "materials to
avoid").

Transport information

Shippingopen allclose all
SpecialProvisionsopen allclose all
Shippingopen allclose all
Remarksopen allclose all

Marine transport (UN RTDG/IMDG)

Shippingopen allclose all
Remarksopen allclose all
Shippingopen allclose all
Remarksopen allclose all
SpecialProvisionsopen allclose all

Exposure controls / personal protection

Personal protective equipment:
Respiratory protection Canister type A or ABEK P3 protection
Hand protection Butyl rubber gloves (best Butyl II) (0.7mm)
Eye protection Chemical safety goggles
Skin and body protection Body covering clothes and boots
Hygiene measures Do not eat, smoke or drink where material is handled, processed or stored. Wash
hands thoroughly after handling and before eating or smoking. Safety shower and
eye bath should be provided.

Stability and reactivity

Reactivity None known
Stability Stable under normal conditions
Possibility of hazardous reactions Not expected to occur
Conditions to avoid None known
Materials to avoid Strong oxidants.
Hazardous decomposition products NOx, HBr & CO

Disposal considerations

Waste disposal Dissolve or mix the material with a combustible solvent and burn in a chemical
incinerator equipped with an afterburner and scrubber
Observe all federal, state and local environmental regulations when disposing of
this material.