Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
21 July 2010 to 20 January 2011
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP study conducted in accordance with an internationally recognised method
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
GLP compliance:
yes (incl. QA statement)
Type of method:
other: Sieving and image analysis (microscopy)
Type of distribution:
mass based distribution
Percentile:
D50
Remarks on result:
other: Migrated from fields under 'Mass median diameter' as D50 percentile. No source field for Standard deviation.

Particle size

% Mass

(µm)

Test 1

Test 2

Test 3

Test 4

Test 5

Test 6

Mean

 

105 - 130

60.0 - 105

30.0 - 60.0

10.4 - 30.0

0.5 - 10.4

 

39.3

27.5

18.6

13.9

0.7

 

25.0

36.8

23.8

13.5

0.9

 

31.1

44.8

15.9

7.6

0.5

 

19.7

46.5

21.0

11.9

0.8

 

18.2

50.4

22.7

7.8

0.9

 

8.4

56.5

26.2

8.5

0.4

 

23.6

43.8

21.4

10.5

0.7

Conclusions:
The results indicated that 0.7% w/w of MPP was smaller than 10 µm.

Description of key information

The results indicate that 0.7% w/w of MPP was smaller than 10 µm.

Additional information

The particle size distribution was determined by a combination of sieving and image analysis with combination of the results to produce a mass distribution. The results indicate that only a very small proportion of MPP is of respirable size (0.7% <10µm) and it can be expected not to present an inhalation hazard.