Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11 Apr 2011
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Guideline study (VDI 2263.1 and EU A.10)

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2011
Report date:
2011

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.10 (Flammability (Solids))
Qualifier:
according to guideline
Guideline:
other: VDI 2263, sheet 1

Test material

Constituent 1
Reference substance name:
Montan waxes, type NaV 101
IUPAC Name:
Montan waxes, type NaV 101
Details on test material:
Test Item: Licomont NaV 101 P

Results and discussion

Pyrophoric solids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.
Pyrophoric liquids
Test procedure:
ignition time on contact with air
Remarks:
Ignition on contact with air refers to either Pyrophoric solids or Pyrophoric liquids depending on physical state (migrated information).
Remarks on result:
no ignition on contact with air (not further specified)
Remarks:
corresponding to 'no' in migrated source record.

Any other information on results incl. tables

The test item showed no reaction when a flame was applied as ignition source at ambient temperature.

The test item caught fire briefly when a hot platinum wire was applied as ignition source. The flame extinguished rapidly after removal of the hot platinum wire.

No fire spreading was observed. The test item melted.

Therefore, determination of the burning rate was not required.

The combustion behaviour of the product at ambient temperature is characterized by the combustion number BZ 2 (catches fire briefly and extinguishes rapidly).

Applicant's summary and conclusion

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
The test item is non flammable (BZ 2).
Executive summary: