Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Guideline study (ISO 11357); basic data given.

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2012
Report date:
2012

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: ISO 11357
GLP compliance:
no
Type of method:
differential scanning calorimetry

Test material

Constituent 1
Reference substance name:
Montan waxes, type KPS
IUPAC Name:
Montan waxes, type KPS
Details on test material:
Product Name: Licowax KPS FL
Purity: app. 100%

Results and discussion

Boiling point
Key result
Decomposition:
yes
Decomp. temp.:
>= 203.5 °C

Any other information on results incl. tables

A boiling point is not detectable, because of decomposition starting at 203.5 °C.

Applicant's summary and conclusion

Conclusions:
The test substance decomposes instead of boiling at 203.5 °C.
Executive summary:

The boiling point of the test substance was investigated by a Differential Scanning Calorimetry (DSC) measurement according to ISO 11357. The test substance decomposes (starting from 203.5 °C) instead of boiling.