Registration Dossier

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 110 (Particle Size Distribution / Fibre Length and Diameter Distributions)
Version / remarks:
Screening Test
GLP compliance:
yes (incl. QA statement)
Type of method:
sieving
Type of particle tested:
primary particle
Type of distribution:
mass based distribution
No.:
#1
Size:
< 100 µm
Distribution:
38.9 %
Remarks on result:
other:
Remarks:
The proportion of test item < 100 µm was 38.9 %.

The results of the sieving procedure are shown below:

 Measurement

Result 

Mass of test item transferred to sieve 

10.04g

 Mass of test item passed through sieve

3.87g

Proportion of test item <100µm 

38.9%
Conclusions:
The proportion of rhodium acetate < 100 μm was 38.9%.
Executive summary:

Tremain and Atwal (2011) is a GLP compliant study following OECD guideline 110 (screening method) and is considered suitable for use as the key study for this endpoint.

The proportion of rhodium acetate < 100 μm was 38.9%.

Description of key information

The proportion of rhodium acetate < 100 μm was 38.9%.

Additional information

Tremain and Atwal (2011) is a GLP compliant study following OECD guideline 110 (screening method) and is considered suitable for use as the key study for this endpoint.

The proportion of rhodium acetate < 100 μm was 38.9%.