Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Environmental fate & pathways

Endpoint summary

Administrative data

Description of key information

Hydrolysis

In accordance with column 2 of Annex VIII of the REACH regulation, testing for this endpoint is scientifically not necessary and does not need to be conducted since the test chemical is readily biodegradable.

Biodegradation in water

42-days Closed Bottle test following the OECD guideline 301 D to determine the ready biodegradability of the test item (Experimental study report, 2018). The study was performed at a temperature of 20°C. The test system included control, test item and reference item. Polyseed was used as a test inoculum for this study. The concentration of test and reference item (Sodium Benzoate) chosen for both the study was 4 mg/L, while that of inoculum was 32 ml/l. OECD mineral medium was used for the study. ThOD (Theoretical oxygen demand) of test and reference item was determined by calculation. % degradation was calculated using the values of BOD and ThOD for test item and reference item. The % degradation of procedure control (reference item) was also calculated using BOD & ThOD and was determined to be 73.49%. Degradation of Sodium Benzoate exceeds 46.38% on 7 days & 60.24% on 14th day. The activity of the inoculum was thus verified and the test can be considered as valid. The BOD42 value of test chemical was observed to be 0.5 mgO2/mg. ThOD was calculated as 0.83 mgO2/mg. Accordingly, the % degradation of the test item after 42 days of incubation at 20 ± 1°C according to Closed Bottle test was determined to be 60.24%. Based on the results, the test item, under the test conditions, was considered to be readily biodegradable in nature.

Bioaccumulation: aquatic / sediment

In accordance with column 2 of Annex IX of the REACH regulation, testing for this endpoint is scientifically not necessary and does not need to be conducted since the test chemical has a low potential for bioaccumulation based on logKow ≤ 3.

Adsorption / desorption

The adsorption coefficient Koc in soil and in sewage sludge of test chemical was determined by the Reverse Phase High Performance Liquid Chromatographic method according to OECD Guideline No. 121 for testing of Chemicals(Experimental study report, 2018). The solutions of the test substance and reference substances were prepared in appropriate solvents. A test item solution was prepared by accurately weighing 4 mg of test item and diluted with methanol up to 10 ml. Thus, the test solution concentration was 400 mg/l. The pH of test substance was 8.0. Each of the reference substance and test substance were analysed by HPLC at 210 nm. After equilibration of the HPLC system, Urea was injected first, the reference substances were injected in duplicate, followed by the test chemical solution in duplicate. Reference substances were injected again after test sample, no change in retention time of reference substances was observed. Retention time tR were measured, averaged and the decimal logarithms of the capacity factors k were calculated. The graph was plotted between log Koc versus log k(Annex - 2).The linear regression parameter of the relationship log Koc vs log k were also calculated from the data obtained with calibration samples and therewith, log Koc of the test substance was determined from its measured capacity factor. The reference substances were chosen according to estimated Koc range of the test substance and generalized calibration graph was prepared . The reference substances were Benzamide, 4- chloroaniline, 4-methylaniline(p-Tolouidine), N-methylaniline, Nitrobenzene, 4-Nitrobenzamide, N,Ndimethylbenzamide, N-methylbenzamide, 2 - nitrophenol having Koc value ranging from 1.239 to 2.47. The Log Koc value of test chemical was determined to be 1.558±0.010 dimensionless at 25°C.This log Koc value indicates that the substance has a low sorption to soil and sediment and therefore have moderate migration potential to ground water.

Additional information

Hydrolysis

In accordance with column 2 of Annex VIII of the REACH regulation, testing for this endpoint is scientifically not necessary and does not need to be conducted since the test chemical is readily biodegradable.

Biodegradation in water

42-days Closed Bottle test following the OECD guideline 301 D to determine the ready biodegradability of the test item (Experimental study report, 2018). The study was performed at a temperature of 20°C. The test system included control, test item and reference item. Polyseed was used as a test inoculum for this study. The concentration of test and reference item (Sodium Benzoate) chosen for both the study was 4 mg/L, while that of inoculum was 32 ml/l. OECD mineral medium was used for the study. ThOD (Theoretical oxygen demand) of test and reference item was determined by calculation. % degradation was calculated using the values of BOD and ThOD for test item and reference item. The % degradation of procedure control (reference item) was also calculated using BOD & ThOD and was determined to be 73.49%. Degradation of Sodium Benzoate exceeds 46.38% on 7 days & 60.24% on 14th day. The activity of the inoculum was thus verified and the test can be considered as valid. The BOD42 value of test chemical was observed to be 0.5 mgO2/mg. ThOD was calculated as 0.83 mgO2/mg. Accordingly, the % degradation of the test item after 42 days of incubation at 20 ± 1°C according to Closed Bottle test was determined to be 60.24%. Based on the results, the test item, under the test conditions, was considered to be readily biodegradable in nature.

Bioaccumulation: aquatic / sediment

In accordance with column 2 of Annex IX of the REACH regulation, testing for this endpoint is scientifically not necessary and does not need to be conducted since the test chemical has a low potential for bioaccumulation based on logKow ≤ 3.

Adsorption / desorption

The adsorption coefficient Koc in soil and in sewage sludge of test chemical was determined by the Reverse Phase High Performance Liquid Chromatographic method according to OECD Guideline No. 121 for testing of Chemicals(Experimental study report, 2018). The solutions of the test substance and reference substances were prepared in appropriate solvents. A test item solution was prepared by accurately weighing 4 mg of test item and diluted with methanol up to 10 ml. Thus, the test solution concentration was 400 mg/l. The pH of test substance was 8.0. Each of the reference substance and test substance were analysed by HPLC at 210 nm. After equilibration of the HPLC system, Urea was injected first, the reference substances were injected in duplicate, followed by the test chemical solution in duplicate. Reference substances were injected again after test sample, no change in retention time of reference substances was observed. Retention time tR were measured, averaged and the decimal logarithms of the capacity factors k were calculated. The graph was plotted between log Koc versus log k(Annex - 2).The linear regression parameter of the relationship log Koc vs log k were also calculated from the data obtained with calibration samples and therewith, log Koc of the test substance was determined from its measured capacity factor. The reference substances were chosen according to estimated Koc range of the test substance and generalized calibration graph was prepared . The reference substances were Benzamide, 4- chloroaniline, 4-methylaniline(p-Tolouidine), N-methylaniline, Nitrobenzene, 4-Nitrobenzamide, N,Ndimethylbenzamide, N-methylbenzamide, 2 - nitrophenol having Koc value ranging from 1.239 to 2.47. The Log Koc value of test chemical was determined to be 1.558±0.010 dimensionless at 25°C.This log Koc value indicates that the substance has a low sorption to soil and sediment and therefore have moderate migration potential to ground water.