Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016-10-24 to 2016-11-30
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
May 2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
September 2003
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: ASTM designation D 7094-04, Flash Point by Modified Continuosly Closed Cup (MCCCFP) Tester
Version / remarks:
November 2004
Deviations:
no
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
51.6 °C
Atm. press.:
101.3 kPa
Remarks on result:
other: mean of 3 replicate measurements

Preliminary test:

The flash point that was observed is 51°C.

Main test:

Three replicate measurements were performed. The flashpoint temperature was corrected to atmospheric pressure 101.3 kPa.

Replicate Flash point (°C) Pressure (kPa) corrected temperature (°C)
1 51.0 98.71 51.6
2 51.0 98.71 51.6
3 51.0 98.71 51.6
Mean (n = 3) 51.6
 SD (n = 3)      0.0
Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
The test item has a flash point of 51.6°C at atmospheric pressure.
Executive summary:

The flash point was determined according to EU Method A.9, closed cup method Pensky-Martens apparatus. Three replicate measurements were performed and the flash point was found to be 51.6°C, corrected to atmospheric pressure.

Description of key information

For this endpoint, one study is available in which the flash point of the test item was determined according to EU Method A.9, closed cup, Pensky-Martens apparatus. The test item was found to have a flash point of 51.6°C at atmospheric pressure (101 325 Pa).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
51.6 °C

Additional information

According to the EU Regulation No. 1272/2008 on the Classification, Labelling and Packaging of Substances and Mixtures (CLP) the substance is considered to be classified as category 3 flammable liquid because the flash point is ≥ 23 °C and ≤ 60 °C (Table 2.6.1).