Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
07-10-2017 – 07-10-2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Justification for type of information:
Experimental test result performed using standard OECD test guidelines
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Principles of method if other than guideline:
The flash point determination of Test item Bis(4-hydroxy-N-methylanilinium) sulphate (CAS No. 55-55-0) was done. The method was closed cup method using Pensky-Martens Flash Point Apparatus.
GLP compliance:
not specified
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Specific details on test material used for the study:
- Name of test material: p-Methylaminophenol sulfate
- IUPAC name: Bis(4-hydroxy-N-methylanilinium) sulphate
- Molecular formula: C14H20N2O6S
- Molecular weight: 344.386 g/mole
- Smiles:CNc1ccc(cc1)O.CNc1ccc(cc1)O.OS(=O)(=O)O
- Inchl: 1S/2C7H9NO.H2O4S/c2*1-8-6-2-4-7(9)5-3-6;1-5(2,3)4/h2*2-5,8-9H,1H3;(H2,1,2,3,4)
- Substance type: Organic
- Physical state: Solid crystalline (off white - white)
Key result
Flash point:
257 °C
Atm. press.:
971.2 hPa
Remarks on result:
other: By closed cup method

TEST DESCRIPTION AND RESULT

 

Method Details

Observations

Remarks if, any

Method

Closed cup method

 

 

Principle of Flash point test

The flash point of a flammable liquid is the lowest temperature at which there will be enough flammable vapor to ignite when an ignition source is applied.

 

Type of method

  Closed cup

 

Flash point apparatus

 Abel’s flash pt apparatus Pensky-Martens flash point apparatus

Pensky-Martens flash point apparatus

Quantity of chemical used

g/ml

5.008

Ignition source

Gas lighter/flame

Gas lighter

Atmospheric pressure

hPa

971.2hPa

Flash point (RESULT)

°C

257°C

Interpretation of results:
other: non flammable
Conclusions:
The flash point of Bis(4-hydroxy-N-methylanilinium) sulphate(CAS No. 55-55-0) was 257°C at 971.2hPa.
Executive summary:

The flash point determination of Bis(4-hydroxy-N-methylanilinium) sulphate (CAS No. 55-55-0) was done following closed cup method using Pensky-Martens flash point apparatus. The flash point was found to be 257°C at 971.2 hPa.

Description of key information

The flash point of Bis(4-hydroxy-N-methylanilinium) sulphate(CAS No. 55-55-0) was 257°C at 971.2hPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
257 °C

Additional information

The flash point determination of Bis(4-hydroxy-N-methylanilinium) sulphate (CAS No. 55-55-0) was done following closed cup method using Pensky-Martens flash point apparatus. The flash point was found to be 257°C at 971.2 hPa.