Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 203-870-1 | CAS number: 111-44-4
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Biodegradation in water and sediment: simulation tests
Administrative data
- Endpoint:
- biodegradation in water: sewage treatment simulation testing
- Type of information:
- experimental study
- Adequacy of study:
- supporting study
- Reliability:
- 4 (not assignable)
- Rationale for reliability incl. deficiencies:
- documentation insufficient for assessment
- Justification for type of information:
- Study conducted according to sound scientific principles. However, while the study has been peer-reviewed, it provides insufficient data to assess the reliability of the results.
Data source
Referenceopen allclose all
- Reference Type:
- publication
- Title:
- Unnamed
- Year:
- 1 986
- Reference Type:
- publication
- Title:
- Unnamed
- Year:
- 1 988
Materials and methods
Test guideline
- Qualifier:
- no guideline available
- Principles of method if other than guideline:
- Alternative water treatment processes were compared to conventional activated sludge system in order to evaluate their relative efficiency to remove 21 listed organic priority pollutants (including Bis(2-chloroethyl)ether). The selected alternative processes were: single-stage high-rate trickling filter, primary treatment with chemical addition, direct filtration of primary effluent, aerated lagoons, and single-stage facultative lagoons. Influent wastewater was spiked with the 21 listed priority pollutants dissolved in toluene. Samples of feed, effluents, and sludges were analyzed for both conventional and priority pollutants.
- GLP compliance:
- no
Test material
- Reference substance name:
- Bis(2-chloroethyl) ether
- EC Number:
- 203-870-1
- EC Name:
- Bis(2-chloroethyl) ether
- Cas Number:
- 111-44-4
- Molecular formula:
- C4H8Cl2O
- IUPAC Name:
- 1-chloro-2-(2-chloroethoxy)ethane
- Test material form:
- liquid
Constituent 1
- Specific details on test material used for the study:
- SOURCE OF TEST MATERIAL
- Source and lot/batch No.of test material: no data
- Expiration date of the lot/batch: no data
- Purity test date: no data
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL: no data
TREATMENT OF TEST MATERIAL PRIOR TO TESTING
- Treatment of test material prior to testing:
- Preliminary purification step (if any):
- Final dilution of a dissolved solid, stock liquid or gel:
- Final preparation of a solid:
FORM AS APPLIED IN THE TEST (if different from that of starting material)
OTHER SPECIFICS:
Study design
- Oxygen conditions:
- aerobic
- Inoculum or test system:
- activated sludge, adapted
- Details on inoculum:
- - Source of activated sludge : Raw wastewater from the Mill Creek Wastewater Treatment Plant located in the vicinity of the Water Engineering Research Laboratory at the Test and Evaluation (T&E) Facility, Cincinnati, Ohio.
- Biomass concentration of raw wastewater: BOD = 279 mg/L; TSS = 487 mg/L
- Pretreatment: Raw wastewater was diluted (1:1) with Mill Creek secondary effluent. Before mixing, the secondary effluent was passed throuh a bed of garnular activated carbon. The objective was to prepapre an inoculum more typical of domestic U.S. wastewater. Two steel columns 74 cm inside diameter (ID) and 3.7 m high, each containing 1.5 m depth of 8 X 30 mesh granular activated carbon were used to treat the Mill Creek secondary effluent. One column normally operated with the other in back wash or standby mode. The carbon was not regenerated during the 8-month study. An equal volume of coarse-screened raw wastewater was then mixed with the carbon column effluent.
- Spiking: the spiking solution containing the 21 priority organic pollutants dissolvec in toluenen was added to the preatreated inoculum in order to reach a concentration of 100 µg/L of each pollutant. The spiked wastewater contained 70 mg/L toluene.
- Equilibration: The spiked wastewater was passed through a static mixer into three closed detention tanks arranged in series to provide time for the priority pollutants to equilibrate with solids in the wastewater. Detention times ranged between 1.2 and 5.6 hours depending on the number of pilot systems in operation. To prevent solids from depositing in the detention tanks at low flows, effluent from the third tank was pumped through a recirculation line back to the first tank. The spiked equilibrated wastewater was pumped from the recirculation line to feed all systems.
- Acclimation: The four biological treatment systems were operated on spiked wastewater for 30 days before the first samples were collected in order to acclimate the biomass to the selected organic pollutants. The primary with chemical addition system and the high-flow direct filtration of primary effluent system were operated only during scheduled sampling periods to reduce the cost of spiking chemicals and associated labor in spike concentrate preparation.
- Biomass concentration (mg/L) used in test: no specified but said to be typical of domestic U.S. wastewater - Duration of test (contact time):
- ca. 8 mo
- Parameter followed for biodegradation estimation:
- test mat. analysis
- Details on study design:
- #####################################################
I. CONVENTIONAL ACTIVATED SLUDGE SYSTEM (= Control):
I.1. Test conditions
- Water flow: 8.2 m3/d (1.5 gpm).
- Return activated sludge (RAS): 2.7 m3/d (= 1/3 of the influent flow).
- Suspended solids concentration: The suspended solids concentra tions in the mixed liquor and RAS were approximately 2000 mg/L and 7000 mg/L, respectively.
- Nominal solid retention time: 7 days.
- Food-to-microorgansim ratio: 0.5 kg chemical oxygen demand (COD) per day per kilogram of mixed liquor suspended solids (MLSS).
I.2. Test System:
Primary clarifier:
- Circular stainless steel tank with a 45° conical bottom (inside diameter = 0.91 m; sidewater depth = 1.5 m).
- Inlet well: diamater = 0.3 m.
- Sludge collector speed = 5 rph.
- Clarifier overflow rate = 12.4 m3/m2/d.
- Hydraulic detention time = 3.2 h.
Aeration basin:
- Five-pass rectangular, stainless steel tank (length = 3.05 m; width = 0.61 m; sidewater depth = 1.37 m).
- Residence time = 7.5 h.
Final clarifier:
- Identical to the Primary Clarifier.
I.3. Test system efficiency (on average):
TSS: 93%; Total COD: 82%; Dissolved COD: 69%; Ammonia: 86%; Total Kjeldahl nitrogen (TKN): 80%; Total phosphorus: 58%.
II. HIGH RATE TRICKLING FILTER SYSTEM:
II.1. Test conditions
- Water flow: 8.2 m3/d (1.5 gpm).
- Return flow: 8.2 m3/d (i.e., 100% of the design wastewater flow).
- Surface application rate to the filter: 12.4 m3/m2/d.
- Application rate for the volume of media: 6.6 m3/m3/d.
II.2. Test System:
Primary clarifier: identical to that of the conventional activated sludge system.
Trickling filter system:
- Circular stainless steel tank (height= 2.4 m; Inner diameter = 0.91 m).
- Content: 1.9 m of 3.8 to 7.6 cm crushed slag media.
- Primary effluent and return flow from the bottom of the trickling filter are applied to the media from a motor-driven rotating distributor arm.
Final clarifier: identical to that of the conventional activated sludge system.
II.3. Test system efficiency (on average):
TSS: 76%; Total COD: 47%; Dissolved COD: 26%; Total Kjeldahl nitrogen (TKN): 14%; Total phosphorus: 39%.
III. PRIMARY TREATMENT WITH CHEMICAL ADDITION:
III.1. Test conditions:
- Water flow: 10.9 m3/d (2 gpm).
III.2. Test System:
- Rapid-mix tank (Stainless steel; Inner diameter: 29.5 cm; Liquid depth: 8.9 cm; Detention time: 48 s) equipped with a propeler mixer where alum solution (19 g/L) is flash-mixed with the wastewater (250 mg alum /L of wastewater.
- Rectangular flocculation tank (Width: 0.6 m; Length: 1.6 m; Water depth: 0.4 m; Detention time: 53 min) equipped with two paddle stirrers where gentle agitation produces a settleable floc.
- Final clarifier tank (Inner diameter: 0.95 m; sidewater depth: 1.45 m; Overflow rate: 15.2 m3/d) where the solids are separated from the wastewater.
III.3. Test system efficiency (on average):
TSS: 89%; Total COD: 49%; Dissolved COD: 2%; Total Kjeldahl nitrogen (TKN): 12%.
IV. DIRECT FILTRATION OF PRIMARY EFFLUENT:
IV.1. Test conditions:
- No data
IV.2. Test system:
- Production of primary effluent: spiked wastewater is passed through a circular steel tank (Inner diameter = 2.3 m ID; sidewater depth: 2.7 m; detention
time = 3.9 hours; overflow rate = 17.0 m3/m2 d; wastewater flow = 69.8 m3/d (12.8 gpm)).
- Filtration: commercial pulsed-bed pilot unit (filter: 0.25 m bed of 0.35 mm sand as media; surface loading: 54.5 m3/d; flow: 147 m3/m2/day).
IV.3. Test system efficiency (on average):
TSS: 86%; Total COD: 40%; Total Kjeldahl nitrogen (TKN): 15%; Total phosphorus: 44%.
V. LAGOON SYSTEMS:
V.1. Test conditions:
- Light: 5000°K fluorescent lamps suspended 1.8 m above the water surface (light intensity not specified).
- Light cycle: 14L/8D.
- Feeding of lagoons: facultative lagoon = 0.19 m3 wastewater/d; aerated laggon: 4 x 0.19 m3 wastewater/d.
- Hydraulic detention time: facultative lagoon = 25.6 d; aerated laggon: 6.4 d.
- Dissolved oxygen concentrations: 0.1 to 0.2 mg/L
V.2. Test system:
- Aerated and facultative lagoons: sections of concrete pipe (Inner diameter = 2.3 m; sidewater depth = 1.2 m; surface area: 4.1 m2; wasterwater volume: 4.8 m3 each).
V.3. Test system efficiency (on average):
- Facultative lagoon: TSS: 84%; Total COD: 65%; Dissolved COD: 42%; Total Kjeldahl nitrogen (TKN): 11%; Total phosphorus: 31%.
- Aerated lagoon: TSS: 85%; Total COD: 60%; Diossolved COD: 42%; Total Kjeldahl nitrogen (TKN): 2%; Total phosphorus: 19%.
#####################################################
SAMPLING:
- Priority pollutants samples: Samples were collected for 2 or 3 consecutive days at approximately 6-week intervals; Grab samples for volatile analysis were collected three times per day in screw-cap glass vials with an inert fluorocarbon polymer-lined septum; Samples were mixed to obtain a daily composite sample. Samples were collected six times per day and composited into one daily sample for semivolatile organics.
- Conventional pollutants samples: 24 hour composite samples were obtained from grab samples collected six times per day; frequency: every other day.
- pH and lakalinity: 3 times per day.
- TSS: daily.
- Samples storage: refrigerated at 4°C until analyzed (addition of preservatives if applicable).
Results and discussion
% Degradation
- % Degr.:
- >= 64 - <= 80
- Parameter:
- test mat. analysis
- Remarks on result:
- other: Activated sludge system
- Transformation products:
- not measured
- Evaporation of parent compound:
- not measured
- Volatile metabolites:
- not measured
- Residues:
- not measured
Any other information on results incl. tables
Table 1. Concentrations of BCEE in waste water feed and effluents and removal by different processes (results from Hannah et al. 1986).
|
Concentration in BCEE (µg/L) |
% removal |
||
|
Mean |
Standard dev. |
Mean |
Standard dev. |
Wastewater feed |
143 |
51 |
- |
- |
Activated sludge* |
30 |
48 |
80 |
31 |
Primary clarification* |
122 |
37 |
6 |
27 |
Primary plus filtration* |
120 |
26 |
20 |
28 |
Chemical clarification* |
114 |
53 |
17 |
40 |
Trickling filter* |
132 |
37 |
-1 |
16 |
Aerated lagoon* |
201 |
41 |
23 |
31 |
Facultative lagoon* |
78 |
28 |
43 |
14 |
* secondary effluent
Table 2. BCEE removal by different processes (results from Hannah et al. 1988).
Concentration in BCEE (µg/L) |
% removal |
|||
|
Mean |
Standard dev. |
Mean |
Standard dev. |
Wastewater feed |
ns |
ns |
- |
- |
Activated sludge* |
74 |
82 |
64 |
38 |
Trickling filter* |
148 |
65 |
ns |
ns |
ns: not specified
* secondary effluent
Applicant's summary and conclusion
Validity criteria
- Validity criteria fulfilled:
- not applicable
- Conclusions:
- Based on a conventional activated sludge treatment, the removal efficiency of Bis(2-chloroethyl) ether was found to vary between 64 +/-38% and 80 +/- 31%.
- Executive summary:
In this peer-reviewed publication (Hannah et al. 1986), the removal of various priority organic pollutants was assessed using different water treatment setups (conventional activated sludge, sand filtration, chemical clarification, trickling filter and aerated or facultative lagoons). The activated sewage sludges were acclimated for 30 days to the priority organic pollutants. Samples were collected daily for 2-3 days at 6 week intervals for c.a. 8 months. The conventional activated sludge treatment, showed the highest efficiency Bis(2-chloroethyl) ether, which achieved 80 +/- 31%. In a sister study (Hannah et al. 1988), the same experimental setup only achieved a removal efficiency of 64 +/- 38% despite the best efforts to hold experimental conditions at a steady state.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.