Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Constituent 1
Reference substance name:
Amyris balsamifera, ext.
EC Number:
291-076-6
EC Name:
Amyris balsamifera, ext.
Cas Number:
90320-49-3
Molecular formula:
Not applicable due to the UVCB nature of the substance.
IUPAC Name:
Essential oil of Amyris obtained from the wood of Amyris balsamifera (Rutaceae) trees by steam distillation.
Test material form:
liquid: viscous
Remarks:
Pale yellow slightly viscous liquid
Details on test material:
Name of test material as cited in study report: Amyris oil
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: at room temperature protected from light

Results and discussion

Flash point
Key result
Remarks on result:
no flash point according to standard method
Remarks:
No flammable vapour/air mixture was produced at temperatures up to boiling (closed cup method)

Applicant's summary and conclusion

Conclusions:
The flash point of Amyris Oil is non-existant
Executive summary:

The test item Amyris Oil has no flash point according to the guidelines EC A.9 / ASTM D93 / ISO 2719.