Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 946-318-1 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Adsorption / desorption
Administrative data
Link to relevant study record(s)
- Endpoint:
- adsorption / desorption: screening
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 1 June 2012 to 4 July 2012
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- guideline study with acceptable restrictions
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 121 (Estimation of the Adsorption Coefficient (Koc) on Soil and on Sewage Sludge using High Performance Liquid Chromatography (HPLC))
- Deviations:
- yes
- Remarks:
- (see "Principles of method if other than guideline")
- Qualifier:
- according to guideline
- Guideline:
- EU Method C.19 (Estimation of the Adsorption Coefficient (KOC) on Soil and Sewage Sludge Using High Performance Liquid Chromatography (HPLC))
- Deviations:
- yes
- Remarks:
- (see "Principles of method if other than guideline")
- Principles of method if other than guideline:
- The guidelines state that the measurement of the adsorption coefficient should be carried out on substances in their ionised and unionised forms. Definite structures were not available to calculate the dissociation constants but it was considered that any acid groups would be carboxylic acids and their dissociation constants would be outside the relevant pH range of the test. Therefore, the test was performed with the mobile phase at an approximately neutral pH.
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- HPLC estimation method
- Media:
- soil/sewage sludge
- Radiolabelling:
- no
- Test temperature:
- No data available.
- Details on study design: HPLC method:
- The test material (0.5061 g) was diluted to 20 mL with tetrahydrofuran to give a concenration of 2.53 x 10^4 g/L.
The sample, dead time and reference standard solutions were injected in duplicate using the following HPLC parameters:
- Apparatus: Agilent Technologies 1100 incorporating autosamples, Polymer Laboratories Evaporative Light Scattering Detector 1000 (ELSD), and workstation
- Column: XSelect cyano 5 µm (150 x 4.6 mm id)
- Column temperature: 30 ºC
- Mobile phases: methanol:water (55:45 v/v) (changed to 100% tetrahydrofuran after the elution of the last reference standard to elute the highly retained test material components)
- pH of mobile phase: 6.5
- Flow rate: 1.0 mL/min
- Injection volume: 5 µL
- UV detector wavelength: dead time and reference standards: 210 nm
- ELSD parameters: nebuliser temperature: 40 ºC; evaporative temperature: 80 ºC; gas flow: 1.0 SLM
The mobile phase was changed to 100% tetrahydrofuran after the elution of the last reference standard to elute the highly retained test components.
DETERMINATION OF DEAD TIME
The dead time was determined by measuring the retention time of formamide (purity 99.6%, 735 mg/L solution in mobile phase).
REFERENCE SUBSTANCES:
- Acetanilide (purity ≥ 99%): 100 mg/L
- Phenol (purity ≥ 99%): 171 mg/L
- Atrazine (purity 98.8%): 100 mg/L
- Isoproturon (purity 99.9%): 109 mg/L
- Triadimenol (purity 98.4%): 101 mg/L
- linuron (purity 99.9%): 100 mg/L
- Naphthalene (purity ≥ 99%): 100 mg/L
- Endosulfan-diol (purity 99.9%): 120 mg/L
- Fenthion (purity 98.3%): 147 mg/L
- Phenanthrene (purity 97%): 106 mg/L
- Diclofop-methyl (purity 99.2%) 102 mg/L
- DDT (purity 98%): 187 mg/L - Type:
- log Koc
- Value:
- > 5.63 dimensionless
- Remarks on result:
- other: no information on temperature available.
- Type:
- Koc
- Value:
- > 427 000 dimensionless
- Remarks on result:
- other: no information on temperature available.
- Details on results (HPLC method):
- The capacity factor was calculated according to:
k' = (tr - t0 / t0)
where:
k' = capacity factor
tr = retention time (min)
t0 = dead time (min)
A correlation of log k' versus log Koc of the calibration standards was plotted using linear regression.
From the plotted data, the linear regression parameters were calculated as:
Slope = 0.350
Intercept = -0.681
Correlation Coefficient (r) = 0.965
The value of log Koc for the test material was calculated as:
Log Koc = Log k' - intercept / slope - Validity criteria fulfilled:
- yes
- Conclusions:
- Under the conditions of the test, the adsorption coefficient (Koc) of the test material was determined to be > 4.27 x 10⁵ (Log Koc > 5.63). This value indicates that the test material is immobile.
- Executive summary:
The adsorption coefficient of the test material was determined in accordance with the standardised guidelines OECD 121 and EU Method C.19, using the HPLC screening method. Under the conditions of the test, the adsorption coefficient (Koc) of the test material was determined to be > 4.27 x 10⁵ (Log Koc > 5.63). This value indicates that the test material is immobile.
- Endpoint:
- adsorption / desorption: screening
- Type of information:
- read-across from supporting substance (structural analogue or surrogate)
- Adequacy of study:
- key study
- Reliability:
- 2 (reliable with restrictions)
- Justification for type of information:
- See read-across justification attached in Section 13.
- Reason / purpose for cross-reference:
- read-across source
- Type:
- log Koc
- Value:
- > 5.63 dimensionless
- Remarks on result:
- other: no information on temperature available
- Type:
- Koc
- Value:
- 427 000 dimensionless
- Remarks on result:
- other: no information on temperature available
Referenceopen allclose all
Table 1: Reference solution data
Standard |
Retention time (mins) |
Mean retention time (mins) |
Capacity factor (k') |
log k' |
log Koc |
|
Injection 1 |
Injection 2 |
|||||
Acetanilide |
2.737 |
2.737 |
2.737 |
0.412 |
-0.385 |
1.25 |
Phenol |
2.664 |
2.625 |
2.645 |
0.365 |
-0.438 |
1.32 |
Atrazine |
3.843 |
3.845 |
3.844 |
0.983 |
-0.00723 |
1.81 |
Isoproturon |
4.187 |
4.175 |
4.181 |
1.16 |
0.0635 |
1.86 |
Triadimenol |
5.847 |
5.861 |
5.854 |
2.02 |
0.305 |
2.40 |
Linuron |
6.142 |
6.126 |
6.122 |
2.16 |
0.334 |
2.59 |
Naphthalene |
5.141 |
5.143 |
5.142 |
1.65 |
0.218 |
2.75 |
Endosulfan-diol |
7.923 |
7.889 |
7.906 |
3.08 |
0.488 |
3.02 |
Fenthion |
9.418 |
9.401 |
9.410 |
3.86 |
0.586 |
3.31 |
Phenanthrene |
10.204 |
10.216 |
10.210 |
4.27 |
0.630 |
4.09 |
Diclofop-methyl |
14.816 |
14.833 |
14.825 |
6.65 |
0.823 |
4.20 |
DDT |
31.075 |
31.038 |
31.057 |
15.0 |
1.18 |
5.63 |
Table 2: Test material solution data
Injection |
Retention time (mins) |
Capacity factor (k') |
log k' |
log Koc |
1 |
> 31.1 |
> 15.0 |
> 1.18 |
> 5.63 |
2 |
> 31.1 |
> 15.0 |
> 1.18 |
> 5.63 |
Description of key information
The Log Koc of an analogue test material (EC 265-205-1) was determined to be > 5.63 according to a GLP compliant key study (Fox, 2012) performed according to OECD 121 and EU Method C.19.
Key value for chemical safety assessment
- Koc at 20 °C:
- 427 000
Additional information
The key study (Fox, 2012) is a GLP compliant study which was performed in accordance with standardised guidelines OECD 121 and EU Method C.19 with a sufficient level of detail to assess the quality of the presented results. The Log Koc of an analogue test material (EC 265-205-1) was determined, using the HPLC screening method to be > 5.63. This value indicates that the test material is immobile.
[LogKoc: 5.63]
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.