Registration Dossier

Diss Factsheets

Physical & Chemical properties

Explosiveness

Currently viewing:

Administrative data

Endpoint:
explosive properties of explosives
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1992-06-05 to 1992-06-09
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
1992
Report date:
1992

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
EU Method A.14 (Explosive properties)
Deviations:
no
GLP compliance:
yes

Test material

Constituent 1
Chemical structure
Reference substance name:
3-(2-{4-[(Z)-(2,4-DIFLUOROPHENYL)(HYDROXYIMINO)METHYL]PIPERIDIN-1-YL}ETHYL)-2-METHYL-6,7,8,9-TETRAHYDRO-4H-PYRIDO[1,2-A]PYRIMIDIN-4-ONE
EC Number:
603-689-1
Cas Number:
132961-05-8
Molecular formula:
C23H28F2N4O2
IUPAC Name:
3-(2-{4-[(Z)-(2,4-DIFLUOROPHENYL)(HYDROXYIMINO)METHYL]PIPERIDIN-1-YL}ETHYL)-2-METHYL-6,7,8,9-TETRAHYDRO-4H-PYRIDO[1,2-A]PYRIMIDIN-4-ONE
Test material form:
solid: particulate/powder
Specific details on test material used for the study:
No data

Results and discussion

Small-scale preliminary testsopen allclose all
Parameter:
other: More sensitive to shock than m-dinitrobenzene
Remarks on result:
not measured/tested
Parameter:
other: More sensitive to friction than m-dinitrobenzene
Remarks on result:
not measured/tested
Parameter:
other: Explosive under influence of flame
Remarks on result:
negative (not further specified)

Any other information on results incl. tables

Results

Thermal sensitivity (effect of flame): The total heating time is 300 seconds. The substance does not explode under the effect of flame.

Mechanical sensitivity (shock):

10 times negative, sensitivity > 39.2 Nm

The substance is not sensitive to shock.

Mechanical sensitivity (friction)

Results: 6 times negative, sensitivity > 360 N

The substance T001624 is not sensitive to friction

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The test substance T001624 is not sensitive to friction, nor to shock and does not explode under the effect of flame.