Registration Dossier
Registration Dossier
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: 946-440-5 | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates â in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data

Partition coefficient
Administrative data
Link to relevant study record(s)
- Endpoint:
- partition coefficient
- Type of information:
- experimental study
- Adequacy of study:
- key study
- Study period:
- 27 October 2016 to 24 November 2016
- Reliability:
- 1 (reliable without restriction)
- Rationale for reliability incl. deficiencies:
- guideline study
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 117 (Partition Coefficient (n-octanol / water), HPLC Method)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.8 (Partition Coefficient - HPLC Method)
- Deviations:
- no
- GLP compliance:
- yes (incl. QA statement)
- Type of method:
- HPLC method
- Partition coefficient type:
- octanol-water
- Analytical method:
- high-performance liquid chromatography
- Key result
- Type:
- log Pow
- Partition coefficient:
- > 10
- Temp.:
- 40 °C
- pH:
- 7.1
- Details on results:
- RESULTS
- The estimated Log10 Pow for the representative structure of the test item was calculated to be 10.34.
- Typical chromatography for the definitive test is presented in Appendix 2 (attached).
- Retention times of the dead time and retention times, capacity factors (kâ) and Log10 Pow values for the reference standards are shown in Table 9 (attached).
- Retention times, capacity factor and Log10 Pow values determined for the sample are shown in Table 10 (attached). - Conclusions:
- The partition coefficient of the test item was determined to be greater than 1.0 x 10E10 with Log10 Pow > 10.0.
- Executive summary:
GUIDELINE
The determination was carried out using the HPLC method and a procedure designed to be compatible with Method A.8 Partition Coefficient of Commission Regulation (EC) No 440/2008 of 30 May 2008 and Method 117 of the OECD Guidelines for Testing of Chemicals, 13 April 2004.
RESULTS
The partition coefficient of the test item was determined to be greater than 1.0 x 10E10 with Log10 Pow > 10.0.
Reference
DISCUSSION
- The result from the preliminary test and as the test item was a complex mixture indicated that the HPLC method was suitable for determination of partition coefficient for this test item.
- The test was modified from that stated in the guidelines to allow assessment of the partition coefficient up to a value of Log10 Pow 10.0 by the use of additional reference standards. Additionally, the mobile phase contained only 20 % water, instead of the guideline recommended minimum of 25 %, to reduce the retention time of the highly retained additional reference standards.
- The mobile phase pH was unadjusted as the representative structure for the test item had no functionality with a dissociation constant within the environmentally relevant range.
- There is a peak integrated in the sample chromatography at approximately 48 mins which was calculated to have a Log10 Pow of 9.61. This was not included in the final test result as it was considered not significant to the test item overall with it being less than 0.2 % by peak area.
Description of key information
The partition coefficient of the test item was determined to be greater than 1.0 x 10E10 with Log10 Pow > 10.0 (OECD 117 and EU Method A.8).
Key value for chemical safety assessment
Additional information
GUIDELINE
The determination was carried out using the HPLC method and a procedure designed to be compatible with Method A.8 Partition Coefficient of Commission Regulation (EC) No 440/2008 of 30 May 2008 and Method 117 of the OECD Guidelines for Testing of Chemicals, 13 April 2004.
RESULTS
The partition coefficient of the test item was determined to be greater than 1.0 x 10E10 with Log10 Pow > 10.0.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.