Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
November 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Constituent 1
Chemical structure
Reference substance name:
3,5-dimethylhex-3-en-2-ol
EC Number:
614-095-7
Cas Number:
676532-41-5
Molecular formula:
C8H16O
IUPAC Name:
3,5-dimethylhex-3-en-2-ol
Test material form:
liquid
Specific details on test material used for the study:
Batch: SC00020774

Results and discussion

Flash point
Key result
Flash point:
60 °C
Atm. press.:
101 325 Pa

Applicant's summary and conclusion

Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Executive summary:

The results of the main tests are:

 

First determination:             Flash point, corrected for atmospheric pressure: 59.0°C

Second determination:      Flash point, corrected for atmospheric pressure: 60.5°C

The results of the two tests were averaged and rounded off to the nearest 0.5°C to obtain the final flash point value:

 

 Flash pointSecodemol: 60.0°C.