Registration Dossier

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Description of key information

The following vapour pressure values for the test item were extrapolated from the experimental data (vapour pressure balance):

Based on the measured vapour pressure at 80 °C (vapour pressure balance), the following upper limit vapour pressure values for the test item were calculated:

T / °C

p / hPa

p / Pa

20

< 1×10-8

< 1×10-6

25

< 1×10-7

< 1×10-5

50

< 1× 10-6

< 1× 10-4

 

Key value for chemical safety assessment

Vapour pressure:
0 Pa
at the temperature of:
25 °C

Additional information