Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammable solids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
28 September 2010 to 30 November 2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: GLP Compliant, guideline study, available as unpublished report, acceptable without restrictions
Qualifier:
equivalent or similar to guideline
Guideline:
UN Manual of Tests and Criteria: Test N.1 (Test method for readily combustible solids)
Deviations:
not specified
GLP compliance:
yes (incl. QA statement)
Test procedure:
burning rate test: preliminary screening test
Remarks on result:
other: Pile failed to ignite during the two minutes that the Bunsen flame was applied..

Pile failed to ignite during the two minutes that the Bunsen flame was applied..

Interpretation of results:
non flammable
Remarks:
Migrated information
Conclusions:
Hexachloroplatinic acid is not classified as a readily combustible solid under Division 4.1 as it failed to ignite in the preliminary screening test.
Executive summary:

This is a GLP compliant study following N1 guideline and is considered reliable and suitable for use as the key study for this endpoint. Hexachloroplatinic acid is not classified as a readily combustible solid under Division 4.1 as it failed to ignite in the preliminary screening test.

Description of key information

Hexachloroplatinic acid is not classified as a readily combustible solid under Division 4.1 as it failed to ignite in the preliminary screening test.

Key value for chemical safety assessment

Flammability:
non flammable

Additional information

Walker and White (2011) is a GLP compliant study following N1 method and is considered to be suitable for use as the key study for this endpoint. Hexachloroplatinic acid is not classified as a readily combustible solid under Division 4.1 as it failed to ignite in the preliminary screening test.

Justification for classification or non-classification

Based on experimental data following a standard test guideline, hexachloroplatinic acid is not classified as a readily combustible solid under Division 4.1 as it failed to ignite in the preliminary screening test.