Registration Dossier

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
calculation (if not (Q)SAR)
Adequacy of study:
key study
Study period:
2006
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
other: Done in accordance with standard testing method however not under GLP.
Justification for type of information:
A discussion and report on the read across strategy is given as an attachment in IUCLID Section 13.
Reason / purpose for cross-reference:
read-across: supporting information
Qualifier:
according to guideline
Guideline:
other: ASTM D2879
GLP compliance:
no
Remarks:
estimated by calculation
Type of method:
other: calculated
Key result
Temp.:
25 °C
Vapour pressure:
0.1 kPa
Conclusions:
Reported vapour pressure is 0.1 kPa at 25°C.
Executive summary:

The reported vapour pressure of isododecane is 0.1 kPa at 25 °C (company data).

Description of key information

This data is being read across from the source study that tested isododecane based on analogue read across. A discussion and report on the read across strategy is given as an attachment in IUCLID Section 13.

The reported vapour pressure of isododecane is 0.1 kPa at 25°C (company data).

Key value for chemical safety assessment

Vapour pressure:
0.1 kPa
at the temperature of:
25 °C

Additional information