Registration Dossier

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-03
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods with acceptable restrictions
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Deviations:
no
GLP compliance:
no
Type of method:
equilibrium method closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Flash point:
69 °C
Atm. press.:
1 013 mBar
Interpretation of results:
Category 4 (combustible liquids) based on GHS criteria
Conclusions:
The flash point of the test item was determined to be 69 °C. Therefore, the test item is classified as Category 4 Flammable liquid according to GHS criteria.
Executive summary:

A study was conducted according to ISO 3679 to determine flash point of the test item using a rapid equilibrium closed cup method. The flash point was determined to be at 69.0 °C at 1013 mbar.

Description of key information

The flash point of the test item was determined to be 69 °C. Therefore, the test item is classified as Category 4 Flammable liquid according to GHS criteria.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
69 °C

Additional information

A study was conducted according to ISO 3679 to determine flash point of the test item using a rapid equilibrium closed cup method. The flash point was determined to be at 69.0 °C at 1013 mbar.