Registration Dossier

Diss Factsheets

Environmental fate & pathways

Biodegradation in water: screening tests

Administrative data

Endpoint:
biodegradation in water: ready biodegradability
Data waiving:
study technically not feasible
Justification for data waiving:
the study does not need to be conducted because the substance is inorganic
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
appearance / physical state / colour
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
data from handbook or collection of data
Principles of method if other than guideline:
The apppearnace and physical state was determined by visual observation
GLP compliance:
not specified
Physical state at 20°C and 1013 hPa:
solid
Key result
Form:
solid: crystalline
Remarks:
tetragonal, hygroscopic
Colour:
yellow
Odour:
odourless
Substance type:
inorganic
Conclusions:
The test substance was a yellow, tetragonal, crystalline, hygroscopic and odourless inorganic solid at 20°C and 1013 hPa.
Executive summary:

The test substance was a yellow, tetragonal, crystalline, hygroscopic and odourless inorganic solid at 20°C and 1013 hPa (Haynes, 2015).

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion