Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
equivalent or similar to guideline
Guideline:
ASTM D93 (Standard test methods for flash point by pensky-martens closed cup tester)
Deviations:
no
Qualifier:
equivalent or similar to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Dynamic viscosity of test material:
0.957 g/cm3
Key result
Flash point:
112 °C
Atm. press.:
1 atm
Conclusions:
The Flash point of Cederwood Texas Crude oil is 112°C at 1 atm.
Executive summary:

The test item Cederwood Texas Oil crude has a flash point of 112°C at 1 atm according to the regulation EU Method A.9 (flash point).

Description of key information

The Flash point of Cedarwood Texas oil - Crude was found to be 112ºC at 1 atm.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
112 °C

Additional information