Physical & Chemical properties

Melting point / freezing point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
melting point/freezing point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017
Reliability:
1 (reliable without restriction)
Qualifier:
according to guideline
Guideline:
other: ASTM D1177 Standard Test Method for Freezing Point of Aqueous Engine Coolants.
Principles of method if other than guideline:
This test method involves the determination of the time-temperature curve prior to freezing and the determination of the horizontal or flattened portion of the freezing curve. The freezing point is taken as the intersection of projections of the cooling curve and the freezing curve. If the solution supercools, the freezing point is the maximum temperature reached after supercooling.
GLP compliance:
no
Type of method:
method to determine freezing temperature
Melting / freezing pt.:
ca. -10 °C
Atm. press.:
ca. 101.325 kPa
Conclusions:
The freezing point of the test material is -10°C.

Description of key information

Key value for chemical safety assessment

Melting / freezing point at 101 325 Pa:
-10 °C