Registration Dossier

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
March 11, 2014
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ASTM E659 (Standard test method for autoignition temperature of liquid chemicals)
GLP compliance:
no
Key result
Auto-ignition temperature:
408 °C
Atm. press.:
739.5 mm Hg

Lag Time was 30 seconds. No cool flame observed. Hot flame observed.

Conclusions:
The autoignition temperature of OFPMA was determined according to the ASTM E659. The lowest temperature at which a hot flame was observed was 408°C at 739.5 mmHg with a lag time of 30 seconds. The autoignition temperature of OFPMA is 408°C.

Description of key information

The autoignition temperature of OFPMA was determined according to the ASTM E659. The lowest temperature at which a hot flame was observed was 408°C at 739.5 mmHg with a lag time of 30 seconds. The autoignition temperature of OFPMA is 408°C.

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
408 °C

Additional information