Registration Dossier

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
self-ignition of dust accumulation
Type of information:
experimental study
Adequacy of study:
other information
Study period:
August 29, 2001
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
test procedure in accordance with national standard methods
Qualifier:
according to guideline
Guideline:
other: VDI 2263, Sheet 1
Deviations:
no
GLP compliance:
no
Key result
Remarks on result:
other: no self ignition under the test conditions

The substance could not be ignited in the modified Hartmann Rohr apparatus.

The test substance is not a readily combustible solid in the sense of Guideline EEC/79/831 test A.10.

Conclusions:
The substance could not be ignited in the modified Hartmann Rohr apparatus.
The test substance is not a readily combustible solid in the sense of Guideline EEC/79/831 test A.10.

Description of key information

The substance could not be ignited in the modified Hartmann Rohr apparatus.

The test substance is not a readily combustible solid in the sense of Guideline EEC/79/831 test A.10.

Key value for chemical safety assessment

Additional information

The substance could not be ignited in the modified Hartmann Rohr apparatus.

The test substance is not a readily combustible solid in the sense of Guideline EEC/79/831 test A.10.