Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
auto-ignition temperature (liquids)
Data waiving:
study scientifically not necessary / other information available
Justification for data waiving:
other:
Cross-reference
Reason / purpose for cross-reference:
data waiving: supporting information
Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2004
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ASTM D3278 (Standard test methods for flash point of liquids by small scale closed-cup apparatus)
Deviations:
no
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus
Flash point:
> 105 °C
Atm. press.:
1 013 hPa
Remarks on result:
no flash point up to 100°C
Interpretation of results:
GHS criteria not met
Conclusions:
flash point > 105C
Executive summary:

The method used was ASTM D3278.

the substance boiled around 103C and the flame was extinguished (by steam?) Above 103C, the flame was still not sustainable despite re-ignition. The study was stopped at 106C with no flash being observed.

Data source

Materials and methods

Results and discussion

Applicant's summary and conclusion