Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Particle size distribution (Granulometry)

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
particle size distribution (granulometry)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015
Reliability:
1 (reliable without restriction)
Qualifier:
no guideline followed
Principles of method if other than guideline:
The particle size distribution of sample was measured using a Cilas 1064 Particle Analyzer
GLP compliance:
yes
Type of method:
Laser scattering/diffraction
Type of distribution:
mass based distribution
Percentile:
D10
Mean:
22.46 µm
Remarks on result:
other: Standard deviation is not available from the instrument.
Percentile:
D50
Mean:
61.81 µm
Remarks on result:
other: Standard deviation is not available from the instrument.
Percentile:
D95
Mean:
110.28 µm
Remarks on result:
other: Standard deviation is not available from the instrument.
Conclusions:
Mean diameter of particles size for 2-hydroxyethyliminodi(acetic acid) was determined to be 61.86 µm using laser scattering/diffraction method.
Executive summary:

Mean diameter of particles size for 2-hydroxyethyliminodi(acetic acid) was determined to be 61.86 µm using laser scattering/diffraction method.

Description of key information

Mean diameter of particles size for 2-hydroxyethyliminodi(acetic acid) was determined to be 61.86 µm using laser scattering/diffraction method.

Additional information