Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
23 September 2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Qualifier:
according to guideline
Guideline:
other: Recommendations on the TRANSPORT OF DANGEROUS GOODS: Manual of Tests and Criteria, 6th edition, New York and Geneva, 2015: Class 3, Flammable Liquids
GLP compliance:
no
Type of method:
non-equilibrium method closed cup
Flash point apparatus:
Pensky-Martens apparatus
Key result
Flash point:
84 °C
Atm. press.:
1 013 hPa

Results

 

Preliminary test

The results of the preliminary test with the search program are summarized in the following table. The result “ignition” is indicated by + and “no ignition” by -.

 

Preliminary test

amount of test item / g

temperature / °C

ignition (+/-)

air pressure / hPa

60.76

84.0

+

1011.6

 

In the preliminary test the lowest temperature where an ignition was observed was 84.0 °C.

 

Main test

The results of the main test are summarized in the following table. The result “ignition” is indicated by + and “no ignition” by -.

 

Main test

amount of test item / g

temperature / °C

ignition (+/-)

air pressure / hPa

flash point (corr.) / °C

60.41

84.0

+

1012.0

84.03

60.43

84.0

+

1012.5

84.01

 

In the main test the lowest temperature where an ignition was observed was 84.0 °C.

The mean measured flash point is corrected to the ambient pressure to be 84.02 °C.

The resulting average corrected flash point rounded down to the nearest multiple of 0.5 °C is 84.0 °C.

 

Final Results

The test item has a flash point of 84.0 °C (average corrected and rounded down to the nearest multiple of 0.5 °C) according to Regulation EC No. 440/2008 Method A.9. Flash Point, DIN EN ISO 2719 (2003).

Conclusions:
A flash point value of 84.0 °C (at 1013 hPa) was determined for the test substance according to E.U. Method A.9.

Description of key information

Flash point: 84.0 °C at 1013 hPa (EU Method A.9, non-equilibrium method closed cup - Pensky-Martens apparatus)

Key value for chemical safety assessment

Flash point at 101 325 Pa:
84 °C

Additional information