Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Description of key information

The test item does'nt ignite by a hot flame from a gas burner. It just melts. The combustion is beyond the specified time frame for flammability of 4 minutes for 200 mm.The test item can not be classified as flammable according to the definition in the Council Regulation (EC) No 440/2008, method A10.

Key value for chemical safety assessment

Flammability:
not classified

Additional information

The flammability (solids) was determined according to the method A10 and GLP. The test item was formed into a particle train. A hot flame from a gas burner with a diameter of about 6 mm is used to ignite the pile at one end. The test item just melts. Therefore the combustion is beyond the specified time frame for flammability of 4 minutes for 200 mm.The test item can not be classified as flammable according to the definition in the Council Regulation (EC) No 440/2008, method A10.

Justification for classification or non-classification