Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2017-03-13
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
ISO 3679 (Determination of flash point - Rapid equilibrium closed cup method)
Deviations:
no
GLP compliance:
not specified
Type of method:
closed cup
Flash point apparatus:
Setaflash apparatus
Key result
Flash point:
39 °C
Atm. press.:
1 013 mBar
Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
Using the closed cup method, the flash point of the test item was determined to be 39 °C at 1013 mbar.
Executive summary:

The flash point of the test item was measured by ISO 3679 with the closed cup method. The flash point was determined to be 39 °C at 1013 mbar.

Description of key information

Using the closed cup method, the flash point of the test item was determined to be 39 °C at 1013 mbar.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
39 °C

Additional information

The flash point of the test item was measured by ISO 3679 with the closed cup method.The flash point was determined to be 39 °C at 1013 mbar.