Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point, other
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016-04-22
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study
Remarks:
ASTM D92
Qualifier:
equivalent or similar to guideline
Guideline:
other: ASTM D92
GLP compliance:
no
Type of method:
open cup
Remarks:
non-equilibrium method
Flash point apparatus:
other: Cleveland Open Cup Flash Tester
Remarks:
non-equilibrium method
Key result
Flash point:
262 °C
Atm. press.:
101.3 kPa
Interpretation of results:
other: EU GHS (CLP) criteria not met
Conclusions:
The flash point is 262°C
Executive summary:

The flash point determined using similar method to ASTM D92, was determined to be 262 °C at 101.3kPa.

Description of key information

The flash point determined using similar method to ASTM D92, was determined to be 262 °C at 101.3kPa.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
262 °C

Additional information

Supporting Informations indicate a flash point of 284 °C and 286 °C at 101.325 kPa. Value chosen in the key study for CSA is the lowest value following a worst-case-approach.