Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2010
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ASTM D56 (Standard test method for flash point by tag closed cup tester)
GLP compliance:
not specified
Type of method:
closed cup
Key result
Flash point:
168 °C
Atm. press.:
1 atm
Interpretation of results:
other: CLP criteria not met
Conclusions:
Under the test conditions, the flash point of the test material was 168 °C (335 °F).
Executive summary:

A study was performed to determine the flash point of the test material according to EU Method A.9 (Flash-Point).

The material was tested in a Tag closed cup tester by using the ASTM D56 method.

Under the test conditions, the flash point of the test material was determined to be 168 °C (335 °F).

Description of key information

The flash point was determined according to EU Method A.9 (Ryan, 2010).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
168 °C

Additional information