Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
20.10.05 - 09.03.06
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Version / remarks:
67/548/EEC
Deviations:
no
Qualifier:
according to guideline
Guideline:
OECD Guideline 104 (Vapour Pressure Curve)
Version / remarks:
1995
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
effusion method: vapour pressure balance
Key result
Temp.:
20 °C
Vapour pressure:
0 hPa
Key result
Temp.:
25 °C
Vapour pressure:
0 hPa
Key result
Temp.:
50 °C
Vapour pressure:
0.002 hPa

Vapor Pressure Balance (Effusion Method)

The vapor pressure was measured in the temperature range of 22 °C to 65 °C. The measured vapor pressures at the corresponding temperatures are listed in the following table:

 

Temperature / °C

Vapor pressure / hPa

22.4

2.5 X 10-5

22.6

3.3 X 10-5

26.2

4.2 X 10-5

29.5

8.4 X 10-5

34.9

1.6 X 10-4

42.2

5.0 X 10-4

47.8

1.6 X 10-3

53.2

3.9 X 10-3

57.2

7.6 X 10-3

58.0

7.6 X 10-3

61.3

1.1 X 10-2

65.0

1.7 x 10-2

 

The values for 20, 25 and 50 °C are calculated, using the Antoine constants.

 

T/°C

p/ hPa

p/ Pa

20

1.5 X 10-5

1.5 X 10-3

25

3.8 X 10-5

3.8 X 10-3

50

2.2 X 10-3

2.2 X 10-1

Conclusions:
The test item had a vapour pressure of 1.5E-5 hPa at 20°C.
Executive summary:

A study was performed according to 67/548/EEC. The vapor pressure was measured in the temperature range of 22 °C to 65 °C. The test item had a calculated vapour pressure of 1.5E-5 hPa at 20°C.

Description of key information

Key value for chemical safety assessment

Vapour pressure:
0 hPa
at the temperature of:
20 °C

Additional information

A study was performed according to 67/548/EEC.The vapor pressure was measured in the temperature range of 22 °C to 65 °C.The test item had a calculated vapour pressure of 1.5E-5 hPa at 20°C.