Registration Dossier

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
guideline study without detailed documentation

Data source

Reference
Reference Type:
other: Certificate of Analysis
Title:
Unnamed
Year:
2015
Report Date:
2015

Materials and methods

Test guideline
Qualifier:
according to
Guideline:
other: ASTM D 92
GLP compliance:
no
Type of method:
open cup
Flash point apparatus:
other: Cleveland open vup

Test material

Reference
Name:
Unnamed
Type:
Constituent
Test material form:
liquid
Remarks:
colorless

Results and discussion

Flash point
Key result
Flash point:
101 °C
Atm. press.:
101 325 Pa

Applicant's summary and conclusion

Conclusions:
The flash point of undecan-2-one is 101°C.
Executive summary:

The test item undecan-2 -one has a flash point of 101°C according to the regulation ASTM D 92.