Registration Dossier

Diss Factsheets

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flammability
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2015
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.13 (Pyrophoric Properties of Solids and Liquids)
GLP compliance:
no

The test item does not ignite and propagate combustion either by burning with flame or smoldering along 200 mm of the pile within 2 minutes test period, therefore the test item is classified as a not flammable solid.

Interpretation of results:
not classified based on GHS criteria
Conclusions:
The test item does not ignite and propagate combustion either by burning with flame or smoldering along 200 mm of the pile within 2 minutes test period, therefore the test item is classified as a not flammable solid.

Description of key information

Key value for chemical safety assessment

Flammability:
not classified

Additional information

Justification for classification or non-classification

The test item does not ignite and propagate combustion either by burning with flame or smoldering along 200 mm of the pile within 2 minutes test period, therefore the test item is classified as a not flammable solid.