Administrative data

Endpoint:
boiling point
Type of information:
experimental study
Adequacy of study:
key study
Study period:
04 Decemeber 2017 - 05 December 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2018
Report date:
2018

Materials and methods

Test guidelineopen allclose all
Qualifier:
according to guideline
Guideline:
OECD Guideline 103 (Boiling Point)
Version / remarks:
1995
Deviations:
no
Qualifier:
according to guideline
Guideline:
EU Method A.2 (Boiling Temperature)
Version / remarks:
2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Ministery of Health, Italy
Type of method:
differential scanning calorimetry

Test material

Constituent 1
Chemical structure
Reference substance name:
2-phenylimidazole
EC Number:
211-581-7
EC Name:
2-phenylimidazole
Cas Number:
670-96-2
Molecular formula:
C9H8N2
IUPAC Name:
2-phenyl-1H-imidazole
Test material form:
solid: flakes

Results and discussion

Boiling point
Key result
Boiling pt.:
350 °C
Atm. press.:
101.325 kPa
Decomposition:
no

Any other information on results incl. tables

First test results

The heat flow record showed an endothermic effect between 270 °C and 429 °C, with peak at 359 °C and onset at 349 °C. The boiling point is 349 °C.

 

Second test results

The heat flow record showed an endothermic effect between 270 °C and 414 °C, with peak at 353 °C and onset at 352 °C. The boiling point is 352 °C.

 

Conclusion

The boiling temperature of the sample is 350 °C (the mean of two measurements).

Applicant's summary and conclusion