Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
comparable to guideline study with acceptable restrictions

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2017
Report date:
2017

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
ISO 2719 (Determination of flash point - Pensky-Martens closed cup method)
Version / remarks:
DIN EN ISO 2719/A
Deviations:
no
GLP compliance:
no
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Constituent 1
Chemical structure
Reference substance name:
p-tert-butylaniline
EC Number:
212-215-9
EC Name:
p-tert-butylaniline
Cas Number:
769-92-6
Molecular formula:
C10H15N
IUPAC Name:
4-tert-butylaniline

Results and discussion

Flash point
Key result
Flash point:
111 °C
Atm. press.:
1 013 hPa

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Conclusions:
The non-GLP study was performed according to DIN EN ISO 2719/A without deviations and therefore reliability of Klimisch 2 has been assigned. The flash point has been determined at 111 °C.
Executive summary:

The flash point of the test substance was determined in a non-GLP test according to DIN EN ISO 2719/A using the closed cup method. The flash point has been determined at 111 °C (1013 hPa).