Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2016
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Deviations:
no
Qualifier:
according to guideline
Guideline:
ISO 13736 (Petroleum products and other liquids - Determination of flash point - Abel closed cup method)
Deviations:
no
Qualifier:
according to guideline
Guideline:
other: UN Transport Regulation Class 3 (2009)
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Remarks:
Consilab
Type of method:
closed cup
Specific details on test material used for the study:
STABILITY AND STORAGE CONDITIONS OF TEST MATERIAL
- Storage condition of test material: ambient temperature (up to 25°C)

OTHER SPECIFICS:
Light yellow liquid, 100% UVCB
Key result
Flash point:
37 °C
Atm. press.:
1 013 hPa
Interpretation of results:
Category 3 (flammable liquids) based on GHS criteria
Conclusions:
In a test according to EC A.9. the flash point of the test item was detemined to 37°C.

Description of key information

In a test according to EC A.9. the flash point of the test item was determined to 37°C.

Key value for chemical safety assessment

Flash point at 101 325 Pa:
37 °C

Additional information

According to the CLP Regulation EC 1272/2008, the substance has to be classified as flammable liquid of category 3 and has to be marked with the warning H226: flammable liquid and vapour.