Registration Dossier

Diss Factsheets

Administrative data

Endpoint:
auto-flammability
Type of information:
experimental study
Adequacy of study:
key study
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2013
Report date:
2013

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: UN No.ST/SG/AC.10/11/Rev.5. Test N.4 "Test Method for Self-heating substances"
Deviations:
no
GLP compliance:
yes (incl. QA statement)

Test material

Constituent 1
Test material form:
solid: particulate/powder

Results and discussion

Relative self-ignition temperature (solids)
Key result
Remarks on result:
no self ignition observed under the test conditions
Remarks:
No exothermic effect of the test substance was observed. It demonstrated that the test substance is “not a self-heating substance”. According to the guideline, no further testing was required. After the experiment, the consistency of the sample was unchanged, i.e. no reaction and/or decomposition of the test substance was observed.

Applicant's summary and conclusion

Conclusions:
The self-heating temperature of 1574 CETONA was investigated by Test 1 of the Modified Bowes-Cameron Cage test.
Based on the results obtained, the test substance is considered “not a self-heating substance”.