Registration Dossier
Registration Dossier
Data platform availability banner - registered substances factsheets
Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.
The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.
Diss Factsheets
Use of this information is subject to copyright laws and may require the permission of the owner of the information, as described in the ECHA Legal Notice.
EC number: - | CAS number: -
- Life Cycle description
- Uses advised against
- Endpoint summary
- Appearance / physical state / colour
- Melting point / freezing point
- Boiling point
- Density
- Particle size distribution (Granulometry)
- Vapour pressure
- Partition coefficient
- Water solubility
- Solubility in organic solvents / fat solubility
- Surface tension
- Flash point
- Auto flammability
- Flammability
- Explosiveness
- Oxidising properties
- Oxidation reduction potential
- Stability in organic solvents and identity of relevant degradation products
- Storage stability and reactivity towards container material
- Stability: thermal, sunlight, metals
- pH
- Dissociation constant
- Viscosity
- Additional physico-chemical information
- Additional physico-chemical properties of nanomaterials
- Nanomaterial agglomeration / aggregation
- Nanomaterial crystalline phase
- Nanomaterial crystallite and grain size
- Nanomaterial aspect ratio / shape
- Nanomaterial specific surface area
- Nanomaterial Zeta potential
- Nanomaterial surface chemistry
- Nanomaterial dustiness
- Nanomaterial porosity
- Nanomaterial pour density
- Nanomaterial photocatalytic activity
- Nanomaterial radical formation potential
- Nanomaterial catalytic activity
- Endpoint summary
- Stability
- Biodegradation
- Bioaccumulation
- Transport and distribution
- Environmental data
- Additional information on environmental fate and behaviour
- Ecotoxicological Summary
- Aquatic toxicity
- Endpoint summary
- Short-term toxicity to fish
- Long-term toxicity to fish
- Short-term toxicity to aquatic invertebrates
- Long-term toxicity to aquatic invertebrates
- Toxicity to aquatic algae and cyanobacteria
- Toxicity to aquatic plants other than algae
- Toxicity to microorganisms
- Endocrine disrupter testing in aquatic vertebrates – in vivo
- Toxicity to other aquatic organisms
- Sediment toxicity
- Terrestrial toxicity
- Biological effects monitoring
- Biotransformation and kinetics
- Additional ecotoxological information
- Toxicological Summary
- Toxicokinetics, metabolism and distribution
- Acute Toxicity
- Irritation / corrosion
- Sensitisation
- Repeated dose toxicity
- Genetic toxicity
- Carcinogenicity
- Toxicity to reproduction
- Specific investigations
- Exposure related observations in humans
- Toxic effects on livestock and pets
- Additional toxicological data
Partition coefficient
Administrative data
Link to relevant study record(s)
- Endpoint:
- partition coefficient
- Type of information:
- read-across based on grouping of substances (category approach)
- Adequacy of study:
- key study
- Study period:
- From 18 July, 2011 to 26 April, 2012
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- guideline study
- Remarks:
- KL2 due to RA
- Justification for type of information:
- Refer to the Quaternary ammonium salts (QAS) category or section 13 of IUCLID for details on the category justification. The study with the read across substance is considered sufficient to fulfil the information requirements as further explained in the provided endpoint summary.
The boiling point temperature of test substance was determined according to OECD 103 and EU Method A.2 Guidelines, in compliance with GLP (using differential scanning calorimetry) (Möller M, 2012).
The boiling point temperature of test substance was determined according to OECD 103 and EU Method A.2 Guidelines, in compliance with GLP (using differential scanning calorimetry) (Möller M, 2012).
- Qualifier:
- according to guideline
- Guideline:
- EU Method A.8 (Partition Coefficient)
- Deviations:
- no
- Qualifier:
- according to guideline
- Guideline:
- OECD Guideline 107 (Partition Coefficient (n-octanol / water), Shake Flask Method)
- Deviations:
- no
- GLP compliance:
- yes
- Type of method:
- shake-flask method to: flask method
- Partition coefficient type:
- octanol-water
- Analytical method:
- other: HPLC-MS
- Key result
- Type:
- log Pow
- Partition coefficient:
- -0.13
- Temp.:
- 20 °C
- Remarks on result:
- other: based on solubility in n-octanol/distilled water
- Key result
- Type:
- log Pow
- Partition coefficient:
- -0.13
- Temp.:
- 20 °C
- Remarks on result:
- other: based on solubility in n-octanol/buffer solutions
- Key result
- Type:
- log Pow
- Partition coefficient:
- 2.39
- Temp.:
- 20 °C
- Remarks on result:
- other: based on solubility in n-octanol/critical micelle concentrations
- Details on results:
- The n-octanol solubility of the test substance as the sum of the solubilities of C8-TMAC, C10-TMAC, C12-TMAC, C14-TMAC, C16-TMAC, C18-TMAC and C18:1-TMAC was 243 g/L (determined at 20.4±0.6°C). According to information supplied by the sponsor, the solubility of the test substance in distilled water and in buffer solutions was 328 g/L (determined at 20.0°C) and the critical micelle concentration is 1 g/L (determined at 20.0 ± 0.1°C).
Hence, the partition coefficients calculated using these solubility values are:
- Based on solubility in distilled water: Pow = 0.74; log Pow = -0.13
- Based on solubility in buffer solutions: Pow = 0.74; log Pow = -0.13
- Based on critical micelle concentration: Pow = 243; log Pow = 2.39 - Conclusions:
- Based on the results of the read across study, the partition coefficient of the test substance, C12-14 TMAC, can be considered to be 2.39.
- Executive summary:
A study was conducted to calculate the partition coefficient of the read across substance, Coco TMAC, according to OECD 107 and EU A.8 guidelines using the quotient of the n-octanol solubility and the water solubility, in compliance with GLP. The n-octanol solubility of the substance as the sum of the solubilities of C8-TMAC, C10-TMAC, C12-TMAC, C14-TMAC, C16-TMAC, C18-TMAC and C18:1-TMAC was determined to be 243 g/L (at 20.4±0.6°C). The solubility of the substance in distilled water and in buffer solutions was 328 g/L (determined at 20.0°C) and the critical micelle concentration was 1 g/L (determined at 20.0 ± 0.1°C).Therefore, the partition coefficient of the substance was calculated to be -0.13, -0.13 and 2.39 at 20°C the quotient of the n-octanol/distilled water, n-octanol/buffer solutions and n-octanol/critical micelle concentrations respectively (Brekelmans, 2012). Based on the results of the read across study, the partition coefficient of the test substance, C12-14 TMAC, can be considered to be 2.39.
- Endpoint:
- partition coefficient
- Type of information:
- (Q)SAR
- Adequacy of study:
- supporting study
- Study period:
- 2016
- Reliability:
- 2 (reliable with restrictions)
- Rationale for reliability incl. deficiencies:
- results derived from a valid (Q)SAR model and falling into its applicability domain, with limited documentation / justification
- Justification for type of information:
- See below under 'Overall remarks, attachments' for applicability domain.
- Qualifier:
- according to guideline
- Guideline:
- other: REACH guidance on QSARs: Chapter R.6. QSARs and grouping of chemicals
- Principles of method if other than guideline:
- Since the test substance is a UVCB with similar constituents varying mainly in carbon chain lengths, the Kow values were estimated for the individual components using the fragment constant methodology of the KOWWIN v1.68 program followed by the determination of an overall weighted-average value using the mole fractions of all the individual components.
- Type of method:
- calculation method (fragments)
- Partition coefficient type:
- octanol-water
- Specific details on test material used for the study:
- Input data for the model: SMILES of the individual constituents:
1. Octyltrimethylammonium chloride (C8): CCCCCCCC[N+](C)(C)C.[Cl-]
2. Decyl-trimethyl ammonium chloride (C10): CCCCCCCCCC[N+](C)(C)C.[Cl-]
3. 1-dodecanaminium, N,N,N-trimethyl-, chloride (C12): CCCCCCCCCCCC[N+](C)(C)C.[Cl-]
4. 1-tetradecanaminium, N,N,N-trimethyl-, chloride (C14): CCCCCCCCCCCCCC[N+](C)(C)C.[Cl-]
5. Cetrimonium chloride (C16): CCCCCCCCCCCCCCCC[N+](C)(C)C.[Cl-]
6. Trimethyloctadecylammonium chloride (C18): CCCCCCCCCCCCCCCCCC[N+](C)(C)C.[Cl-] - Key result
- Type:
- log Pow
- Partition coefficient:
- ca. 1.52
- Remarks on result:
- other: based on the weighted average estimations for the individual constituents
- Conclusions:
- Based on the estimated values for the individual constituents using KOWWIN v1.68 program (EPISuite v 4.1), the weighted average log Kow of the test substance was calculated to be 1.52.
- Executive summary:
The log Kow of the test substance, C12-14 TMAC, was estimated using the atom/fragment constant (AFC) method of KOWWIN v1.68 program (EPISuite v4.1). Since the test substance is a UVCB with similar constituents varying mainly in carbon chain lengths, the Kow values were estimated for the individual components using the fragment constant methodology of the KOWWIN v1.68 program followed by the determination of an overall weighted-average value using the mole fractions of all the individual components. Using SMILES codes as the input parameter, the log Kow values of the individual constituents were estimated to range between -0.74 to 4.17, leading to a weighted average value of 1.52 (US EPA, 2016). The domain applicability evaluation indicated that the molecular weight and number of instances of fragments were within the maximum values of the training set, hence the estimates are considered to be reliable.
Referenceopen allclose all
Log Kow(version 1.68 estimate): -0.74 | Training set | Validation set | |
MW | MW | MW | |
SMILES : CCCCCCCCN(CL)(C)(C)C | ID | 719.92 | 991.5 |
CHEM : | |||
MOL FOR: C11 H26 CL1 N1 | |||
MOL WT : 207.79 | |||
-------+-----+--------------------------------------------+---------+-------- | |||
TYPE | NUM | LOGKOW FRAGMENT DESCRIPTION | COEFF | VALUE | |||
-------+-----+--------------------------------------------+---------+-------- | Max Fragments | Max Fragments | |
Frag | 4 | -CH3 [aliphatic carbon] | 0.5473 | 2.1892 | ID | 13 | 20 |
Frag | 7 | -CH2- [aliphatic carbon] | 0.4911 | 3.4377 | ID | 18 | 28 |
Frag | 1 | >N< [+5 valence; single bonds;no H attach]|-6.6000 | -6.6000 | ID | 1 | 1 |
Frag | 1 | Halogen {-CL,-Br,-F,-I} [Nitrogen attach] | 0.0001 | 0.0001 | ID | 1 | 2 |
Const | | Equation Constant | | 0.2290 | |||
-------+-----+--------------------------------------------+---------+-------- | |||
Log Kow = -0.7440 | |||
Log Kow(version 1.68 estimate): 0.24 | |||
SMILES : CCCCCCCCCCN(CL)(C)(C)C | MW | MW | MW |
CHEM : | ID | 719.92 | 991.5 |
MOL FOR: C13 H30 CL1 N1 | |||
MOL WT : 235.84 | |||
-------+-----+--------------------------------------------+---------+-------- | |||
TYPE | NUM | LOGKOW FRAGMENT DESCRIPTION | COEFF | VALUE | |||
-------+-----+--------------------------------------------+---------+-------- | Max Fragments | Max Fragments | |
Frag | 4 | -CH3 [aliphatic carbon] | 0.5473 | 2.1892 | ID | 13 | 20 |
Frag | 9 | -CH2- [aliphatic carbon] | 0.4911 | 4.4199 | ID | 18 | 28 |
Frag | 1 | >N< [+5 valence; single bonds;no H attach]|-6.6000 | -6.6000 | ID | 1 | 1 |
Frag | 1 | Halogen {-CL,-Br,-F,-I} [Nitrogen attach] | 0.0001 | 0.0001 | ID | 1 | 2 |
Const | | Equation Constant | | 0.2290 | |||
-------+-----+--------------------------------------------+---------+-------- | |||
Log Kow = 0.2382 | |||
Log Kow(version 1.68 estimate): 1.22 | |||
SMILES : CCCCCCCCCCCCN(CL)(C)(C)C | MW | MW | MW |
CHEM : | ID | 719.92 | 991.5 |
MOL FOR: C15 H34 CL1 N1 | |||
MOL WT : 263.90 | |||
-------+-----+--------------------------------------------+---------+-------- | |||
TYPE | NUM | LOGKOW FRAGMENT DESCRIPTION | COEFF | VALUE | |||
-------+-----+--------------------------------------------+---------+-------- | Max Fragments | Max Fragments | |
Frag | 4 | -CH3 [aliphatic carbon] | 0.5473 | 2.1892 | ID | 13 | 20 |
Frag | 11 | -CH2- [aliphatic carbon] | 0.4911 | 5.4021 | ID | 18 | 28 |
Frag | 1 | >N< [+5 valence; single bonds;no H attach]|-6.6000 | -6.6000 | ID | 1 | 1 |
Frag | 1 | Halogen {-CL,-Br,-F,-I} [Nitrogen attach] | 0.0001 | 0.0001 | ID | 1 | 2 |
Const | | Equation Constant | | 0.2290 | |||
-------+-----+--------------------------------------------+---------+-------- | |||
Log Kow = 1.2204 | |||
Log Kow(version 1.68 estimate): 2.20 | |||
SMILES : CCCCCCCCCCCCCCN(CL)(C)(C)C | MW | MW | MW |
CHEM : | ID | 719.92 | 991.5 |
MOL FOR: C17 H38 CL1 N1 | |||
MOL WT : 291.95 | |||
-------+-----+--------------------------------------------+---------+-------- | |||
TYPE | NUM | LOGKOW FRAGMENT DESCRIPTION | COEFF | VALUE | |||
-------+-----+--------------------------------------------+---------+-------- | Max Fragments | Max Fragments | |
Frag | 4 | -CH3 [aliphatic carbon] | 0.5473 | 2.1892 | ID | 13 | 20 |
Frag | 13 | -CH2- [aliphatic carbon] | 0.4911 | 6.3843 | ID | 18 | 28 |
Frag | 1 | >N< [+5 valence; single bonds;no H attach]|-6.6000 | -6.6000 | ID | 1 | 1 |
Frag | 1 | Halogen {-CL,-Br,-F,-I} [Nitrogen attach] | 0.0001 | 0.0001 | ID | 1 | 2 |
Const | | Equation Constant | | 0.2290 | |||
-------+-----+--------------------------------------------+---------+-------- | |||
Log Kow = 2.2026 | |||
Log Kow(version 1.68 estimate): 3.18 | |||
Experimental Database Structure Match: | |||
Name : CETRIMONIUM CHLORIDE | |||
CAS Num : 000112-02-7 | |||
Exp Log P: 3.23 | |||
Exp Ref : POMONA (1987) | |||
SMILES : CCCCCCCCCCCCCCCCN(CL)(C)(C)C | MW | MW | MW |
CHEM : | ID | 719.92 | 991.5 |
MOL FOR: C19 H42 CL1 N1 | |||
MOL WT : 320.01 | |||
-------+-----+--------------------------------------------+---------+-------- | |||
TYPE | NUM | LOGKOW FRAGMENT DESCRIPTION | COEFF | VALUE | |||
-------+-----+--------------------------------------------+---------+-------- | Max Fragments | Max Fragments | |
Frag | 4 | -CH3 [aliphatic carbon] | 0.5473 | 2.1892 | ID | 13 | 20 |
Frag | 15 | -CH2- [aliphatic carbon] | 0.4911 | 7.3665 | ID | 18 | 28 |
Frag | 1 | >N< [+5 valence; single bonds;no H attach]|-6.6000 | -6.6000 | ID | 1 | 1 |
Frag | 1 | Halogen {-CL,-Br,-F,-I} [Nitrogen attach] | 0.0001 | 0.0001 | ID | 1 | 2 |
Const | | Equation Constant | | 0.2290 | |||
-------+-----+--------------------------------------------+---------+-------- | |||
Log Kow = 3.1848 | |||
Log Kow(version 1.68 estimate): 4.17 | |||
SMILES : CCCCCCCCCCCCCCCCCCN(CL)(C)(C)C | MW | MW | MW |
CHEM : | ID | 719.92 | 991.5 |
MOL FOR: C21 H46 CL1 N1 | |||
MOL WT : 348.06 | |||
-------+-----+--------------------------------------------+---------+-------- | |||
TYPE | NUM | LOGKOW FRAGMENT DESCRIPTION | COEFF | VALUE | |||
-------+-----+--------------------------------------------+---------+-------- | Max Fragments | Max Fragments | |
Frag | 4 | -CH3 [aliphatic carbon] | 0.5473 | 2.1892 | ID | 13 | 20 |
Frag | 17 | -CH2- [aliphatic carbon] | 0.4911 | 8.3487 | ID | 18 | 28 |
Frag | 1 | >N< [+5 valence; single bonds;no H attach]|-6.6000 | -6.6000 | ID | 1 | 1 |
Frag | 1 | Halogen {-CL,-Br,-F,-I} [Nitrogen attach] | 0.0001 | 0.0001 | ID | 1 | 2 |
Const | | Equation Constant | | 0.2290 | |||
-------+-----+--------------------------------------------+---------+-------- | |||
Log Kow = 4.1670 |
Description of key information
Partition coefficient of the read across substance, Coco TMAC was calculated using the quotient of the n-octanol solubility and the critical micelle concentrations (CMC), according to OECD Guideline 107 and EU Method A.8 (Brekelmans, 2012).
Key value for chemical safety assessment
- Log Kow (Log Pow):
- 2.39
- at the temperature of:
- 20 °C
Additional information
(based on ratio of n-octanol solubility and CMC of the read across substance). This is supported by a lower weighted average log Kow value of 1.52 estimated for C12 -14 TMAC using KOWWIN v.1.68 of EPISuite v4.1.
Information on Registered Substances comes from registration dossiers which have been assigned a registration number. The assignment of a registration number does however not guarantee that the information in the dossier is correct or that the dossier is compliant with Regulation (EC) No 1907/2006 (the REACH Regulation). This information has not been reviewed or verified by the Agency or any other authority. The content is subject to change without prior notice.
Reproduction or further distribution of this information may be subject to copyright protection. Use of the information without obtaining the permission from the owner(s) of the respective information might violate the rights of the owner.