Registration Dossier

Diss Factsheets

Physical & Chemical properties

Vapour pressure

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
1993
Reliability:
2 (reliable with restrictions)
Rationale for reliability incl. deficiencies:
study well documented, meets generally accepted scientific principles, acceptable for assessment
Qualifier:
no guideline followed
Principles of method if other than guideline:
- Principle of test: Use of an inclined-piston vapor pressure apparatus
- Short description of test conditions:
- Parameters analysed / observed:
GLP compliance:
no
Type of method:
static method
Key result
Test no.:
#1
Temp.:
>= 20 °C
Vapour pressure:
ca. 0.021 mm Hg

Description of key information

Key value for chemical safety assessment

Vapour pressure:
1.69 Pa
at the temperature of:
20 °C

Additional information