Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
11.10.2007
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
comparable to guideline study

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2007
Report date:
2007

Materials and methods

Test guideline
Qualifier:
equivalent or similar to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
According to PN-EN ISO 2719:2007 Determination of flash point - Pensky-Martens closed cup method.
This method corresponds to EU Method A.9
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus

Test material

Constituent 1
Chemical structure
Reference substance name:
2-ethylhexyl (4-chloro-2-methylphenoxy)acetate
EC Number:
249-636-2
EC Name:
2-ethylhexyl (4-chloro-2-methylphenoxy)acetate
Cas Number:
29450-45-1
Molecular formula:
C17H25ClO3
IUPAC Name:
2-ethylhexyl (4-chloro-2-methylphenoxy)acetate
impurity 1
Chemical structure
Reference substance name:
(4-chloro-2-methylphenoxy)acetic acid
EC Number:
202-360-6
EC Name:
(4-chloro-2-methylphenoxy)acetic acid
Cas Number:
94-74-6
Molecular formula:
C9H9ClO3
IUPAC Name:
(4-chloro-2-methylphenoxy)acetic acid
Test material form:
liquid

Results and discussion

Flash point
Key result
Flash point:
>= 133.3 - <= 138.7 °C
Atm. press.:
998 hPa

Applicant's summary and conclusion

Interpretation of results:
GHS criteria not met
Executive summary:

Determination the flash point of MCPA-2H was performed according to standard PN-EN ISO 2719:2007 “Determination of flash point – Pensky-Martens closed cup method”, which corresponds to method A.9. Flash point.

The measured value of flash point of MCPA-2EH is 136 ± 2.7oC.