Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Physical & Chemical properties

Auto flammability

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
auto-ignition temperature (liquids)
Type of information:
experimental study
Adequacy of study:
key study
Study period:
From 22 December 2016 to 02 January 2017
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.15 (Auto-Ignition Temperature (Liquids and Gases))
Version / remarks:
2008
Deviations:
no
Qualifier:
according to guideline
Guideline:
DIN 51794 (Testing of mineral oil hydrocarbons - Determination of ignition temperature)
Version / remarks:
2003
Deviations:
no
Qualifier:
according to guideline
Guideline:
IEC 60079-4 (Electrical apparatus for explosive gas atmospheres. Part 4: Method of test for ignition temperature)
Version / remarks:
1975
Deviations:
no
GLP compliance:
yes
Key result
Auto-ignition temperature:
350 °C
Atm. press.:
>= 1 020.9 - <= 1 035.5 hPa

Table: Results of the auto-ignition temperature measurements

  

Test

Volume
[μL]

Auto-ignition
temperature
[°C]

Ignition delay

[s]

Colour of the flame

Minimum auto-ignition
temperature
[°C]

 

 

 

 

 

 

1

40

369

3

Orange

364

 

70

369

3

Orange

 

 

100

364

3

Orange

 

 

130

366

3

Orange

 

 

 

 

 

 

 

2

50

357

3

Orang

356

 

85

356

3

Orange

 

 

110

357

4

Orange

 

 

 

 

 

 

 

3

60

356

3

Orange

351

 

90

351

4

Orange

 

 

120

360

4

Orange

 

Conclusions:
The auto-ignition temperature at 1021-1036 hPa was determined to be 350°C.
Executive summary:

The auto-ignition temperature of the substance at 1021 -1036 hPa was determined to be 350°C in a GLP study according to EC A.15, DIN 51794 and IEC 79-4.

Description of key information

The auto-ignition temperature of the substance at 1021 -1036 hPa was determined to be 350°C in a GLP study according to EC A.15, DIN 51794 and IEC 79-4.

Key value for chemical safety assessment

Autoflammability / Self-ignition temperature at 101 325 Pa:
350 °C

Additional information