Registration Dossier

Diss Factsheets

Physical & Chemical properties

Flash point

Currently viewing:

Administrative data

Link to relevant study record(s)

Reference
Endpoint:
flash point of flammable liquids
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2012-02-22 - 2012-03-15
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
guideline study
Qualifier:
according to guideline
Guideline:
EU Method A.9 (Flash-Point)
Version / remarks:
2008
Deviations:
no
GLP compliance:
yes (incl. QA statement)
Type of method:
closed cup
Flash point apparatus:
Pensky-Martens apparatus
Remarks:
Pensky-Martens closed cup apparatus
Dynamic viscosity of test material:
No data available.
Data not required for Reach registartion at tonnage 1-10 tpa.
Specific details on test material used for the study:
- Batch n°: PFW090017
- Date CoA: 27.10.2011
- Water content: 0.12%
- Test Substance Name Jeffamine EDR-176
- Chemical Name 3,3-etheylenedioxybis(propylamine)
- CAS number 2997-01-5
- Batch Number PFW090017
- Description Colourless liquid
- Molecular Formula C8H20N2O2
- Molecular Weight 176 g.mol-1
Key result
Flash point:
138.5 °C
Atm. press.:
101.325 kPa
Remarks on result:
other: 138.5°C (corrected for barometric pressure)

Full test results:

 Temperature °C Barometric Pressure (kPa)  Ignition Yes (y) / No (n) 

Halo/Enlarged test

flame?

Yes (y) / No (n)

 116   102.7  n  n
 118   102.7  n  n
 120   102.7  n  n
 122   102.7  n  n
 124   102.7  n  n
 126   102.7  n
 128

  102.7

 n  n
 130   102.7  n  n
132    102.7  n  n
 134   102.7  n  n
 136   102.7  n  y
 138   102.7  n  y
 140   102.7  y  N/A
          Fresh sample
 117  102.6  n  n
 119  102.6  n  n
 121   102.6  n  n
 123   102.6  n  n
 125   102.6  n  n
 127   102.6  n  n
 129   102.6  n  n
 131   102.6  n  n
 133   102.6  n  n
 135   102.6  n  n
 137   102.6  n  y
 139   102.6  y  N/A

Closed cup Flash point Temperature: 138.5°c (corrected for barometric pressure)

Interpretation of results:
GHS criteria not met
Conclusions:
Closed Cup Flash Point Temperature : 138.5°C (corrected for barometric pressure).
Executive summary:

The flash point determination test is conducted in accordance with the procedure described in EU Regulation (EC) 440/2008, Annex Part A test A9.

The Closed Cup Flash Point Temperature was found to be 138.5°C (corrected for barometric pressure).

Description of key information

The flash point determination test is conducted in accordance with the procedure described in EU Regulation (EC) 440/2008, Annex Part A test A9.

The Closed Cup Flash Point Temperature was found to be 138.5°C (corrected for barometric pressure).

Key value for chemical safety assessment

Flash point at 101 325 Pa:
138.5 °C

Additional information