Registration Dossier

Diss Factsheets

Classification & Labelling & PBT assessment

GHS

General Information

Name:
ECP
Implementation:
EU
Type of classification:
self-classification
Remarks:
Substance should be stored below -20°C for quality purposes.

Related composition

Related composition:
ECP

Classificationopen allclose all

Explosives
Reason for no classification:
data conclusive but not sufficient for classification
Flammable gases and chemically unstable gases
Reason for no classification:
data conclusive but not sufficient for classification
Aerosols
Reason for no classification:
data conclusive but not sufficient for classification
Reason for no classification:
hazard class not assessed
Oxidising gases
Reason for no classification:
data conclusive but not sufficient for classification
Gases under pressure
Reason for no classification:
data conclusive but not sufficient for classification
Flammable liquids
Reason for no classification:
data lacking
Flammable solids
Reason for no classification:
data conclusive but not sufficient for classification
Self-reactive substances and mixtures
Hazard category:
Self React. Type F
Hazard statement:
H242: Heating may cause a fire.
Pyrophoric liquids
Reason for no classification:
data conclusive but not sufficient for classification
Pyrophoric solids
Reason for no classification:
data conclusive but not sufficient for classification
Self-heating substances and mixtures
Reason for no classification:
data conclusive but not sufficient for classification
Substances and mixtures which in contact with water emit flammable gases
Reason for no classification:
data conclusive but not sufficient for classification
Oxidising liquids
Reason for no classification:
data conclusive but not sufficient for classification
Oxidising solids
Reason for no classification:
data conclusive but not sufficient for classification
Organic peroxides
Reason for no classification:
data conclusive but not sufficient for classification
Corrosive to metals
Hazard category:
Met. Corr. 1
Hazard statement:
H290: May be corrosive to metals.
Desensitized explosives
Reason for no classification:
data conclusive but not sufficient for classification
Acute toxicity - oral
Reason for no classification:
data lacking
Acute toxicity - dermal
Reason for no classification:
data lacking
Acute toxicity - inhalation
Reason for no classification:
data lacking
Skin corrosion / irritation
Hazard category:
Skin Corr. 1
Hazard statement:
H314: Causes severe skin burns and eye damage.
Serious eye damage / eye irritation
Hazard category:
Eye Damage 1
Hazard statement:
H318: Causes serious eye damage.
Respiratory sensitisation
Reason for no classification:
data lacking
Skin sensitisation
Reason for no classification:
data lacking
Aspiration hazard
Reason for no classification:
data lacking
Reproductive toxicity
Reason for no classification:
data lacking
Effects on or via lactation
Reason for no classification:
data lacking
Germ cell mutagenicity
Reason for no classification:
data lacking
Carcinogenicity
Reason for no classification:
data lacking
1. Specific target organ toxicity - single (STOT-SE)
Reason for no classification:
data lacking
1. Specific target organ toxicity - repeated (STOT-RE)
Reason for no classification:
data lacking
Hazardous to the aquatic environment (acute / short-term)
Reason for no classification:
data lacking
Hazardous to the aquatic environment (long-term)
Reason for no classification:
data lacking
Hazardous to the ozone layer
Reason for no classification:
data lacking

Labelling

Signal word:
Danger

Hazard pictogram

GHS05: corrosion

Hazard statements

H314: Causes severe skin burns and eye damage.
H290: May be corrosive to metals.

Additional labelling requirements

EUH029: Contact with water liberates toxic gas.
Hydrogen chloride (HCl)
EUH014: Reacts violently with water.

Notes