Registration Dossier

Data platform availability banner - registered substances factsheets

Please be aware that this old REACH registration data factsheet is no longer maintained; it remains frozen as of 19th May 2023.

The new ECHA CHEM database has been released by ECHA, and it now contains all REACH registration data. There are more details on the transition of ECHA's published data to ECHA CHEM here.

Diss Factsheets

Administrative data

Endpoint:
vapour pressure
Type of information:
experimental study
Adequacy of study:
key study
Study period:
2009-12-08
Reliability:
1 (reliable without restriction)
Rationale for reliability incl. deficiencies:
other: Test procedure in accordance with national standard methods (ASTM).

Data source

Reference
Reference Type:
study report
Title:
Unnamed
Year:
2009
Report date:
2010

Materials and methods

Test guideline
Qualifier:
according to guideline
Guideline:
other: ASTM-D 2879
Deviations:
no
GLP compliance:
no
Type of method:
isoteniscope

Test material

Constituent 1
Chemical structure
Reference substance name:
4-(α,α-dimethylbenzyl)phenol
EC Number:
209-968-0
EC Name:
4-(α,α-dimethylbenzyl)phenol
Cas Number:
599-64-4
Molecular formula:
C15H16O
IUPAC Name:
4-(α,α-dimethylbenzyl)phenol
Test material form:
solid
Details on test material:
- para-Cumylphenol
- Lot/batch No.: 0852

Results and discussion

Vapour pressure
Temp.:
38 °C
Vapour pressure:
0.001 mBar

Applicant's summary and conclusion